Key result
A novel diagnostic algorithm using the Hounsfield unit ratio and standard deviation on cardiac CT images demonstrated a diagnostic accuracy of 0.95 for detecting left atrial appendage thrombus.
Why the study?
Cardiac CT is expected to become an alternative to TEE for diagnosing LAA thrombi, but a reliable quantitative evaluation method has not been established.
Does a novel cardiac CT algorithm using HU ratio and HU-SD accurately detect LAA thrombus compared to TEE in patients with persistent atrial fibrillation?
Case-Control (n=177)
Blinded to TEE results for CT analysis
No
Does a novel cardiac CT algorithm using HU ratio and HU-SD accurately detect LAA thrombus compared to TEE in patients with persistent atrial fibrillation?
A novel cardiac CT algorithm combining HU ratio and HU-SD provides high diagnostic accuracy (0.95) for detecting LAA thrombus in persistent AF, potentially reducing the need for pre-ablation TEE.
Answers are grounded in this paper and cite their sources.
Should not yet replace TEE pre-ablation; leaves open prospective validation of HU-based CT algorithms in persistent AF.
BACKGROUND: Transesophageal echocardiography (TEE) is currently the gold standard technique for diagnosing left atrial appendage (LAA) thrombi. Cardiac computed tomography (CT) has been expected to become an alternative method to TEE; however, a reliable quantitative evaluation method has not been established. METHODS AND RESULTS: We enrolled 177 patients with persistent atrial fibrillation who underwent both cardiac CT and TEE before catheter ablation. The patients were classified into two groups according to the TEE results: the thrombus group (13 patients) and non-thrombus group (164 patients). The Hounsfield unit (HU) density at the proximal LAA (LAAp) and distal LAA (LAAd) was measured on cardiac CT images. The LAAd/LAAp HU ratio and standard deviation of HU density (HU-SD) at the LAAd were evaluated. We created an algorithm by decision tree analysis to predict LAA thrombus formation using the HU ratio and HU-SD. Definite absence of LAA thrombus (Category-I) was diagnosed for 139 patients by combining the first and second branching of the decision tree (Category-Ia: HU ratio of ≥0.26, Category-Ib: HU ratio of <0.26, HD-SD of ≥26.94). Definite presence of LAA thrombus (Category-Ⅱ) was diagnosed for 3 patients using the third branching of the decision tree (Category-Ⅱ: HU ratio of <0.26 and HU-SD of <13.85). Highly possibility of LAA thrombus (Category-III), but not definite, was diagnosed for the remaining 35 patients; therefore, these patients required diagnostic TEE. The diagnostic accuracy of this algorithm was 0.95. CONCLUSION: We have proposed a reliable algorithm to diagnose LAA thrombus formation using the HU ratio and HU-SD.
No takes yet. Share an insight, caveat, or question.
Tanaka et al. (2021) conducted a case-control in Persistent atrial fibrillation (n=177). Cardiac computed tomography diagnostic algorithm (HU ratio and HU-SD) vs. Transesophageal echocardiography (TEE) was evaluated on Diagnostic accuracy of LAA thrombus formation. A novel diagnostic algorithm using the Hounsfield unit ratio and standard deviation on cardiac CT images demonstrated a diagnostic accuracy of 0.95 for detecting left atrial appendage thrombus.
Synapse has enriched 10 related papers. Consider them for comparative context: