Why the study?
Does electrode size affect the electric potential distribution in cardiac tissue during electrical stimulation?
Does electrode size affect the electric potential distribution in cardiac tissue during electrical stimulation?
Computational modeling demonstrates that during electrical stimulation of cardiac tissue, depolarization is strongest at the electrode edge and the ratio of peak depolarization to hyperpolarization remains close to three across a broad range of electrode sizes.
Answers are grounded in this paper and cite their sources.
Electrode edge effects warrant consideration in experimental stimulation; leaves open human translation and clinical validation.
We investigate the effect of electrode size on the transmembrane potential distribution in the heart during electrical stimulation. The bidomain model is used to calculate the transmembrane potential in a three-dimensional slab of cardiac tissue. Depolarization is strongest under the electrode edge. Regions of depolarization are adjacent to regions of hyperpolarization. The average ratio of peak depolarization to peak hyperpolarization is a function of electrode radius, but over a broad range is close to three.
No takes yet. Share an insight, caveat, or question.
Patel et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: