Key result
Cardiovascular simulation demonstrated that energetic efficiency is higher in an electrically heterogeneous ventricular model compared to a homogeneous model.
Why the study?
Does electrical transmural heterogeneity improve cardiovascular energetic efficiency in ventricular myocardium simulation models?
Does electrical transmural heterogeneity improve cardiovascular energetic efficiency in ventricular myocardium simulation models?
Cardiovascular simulations demonstrate that electrical transmural heterogeneity in the ventricular myocardium is associated with higher energetic efficiency.
Simulation findings do not guide clinical decisions; leaves open whether heterogeneity improves efficiency in vivo.
In this study, we use cardiovascular simulation to gain new insights on the correlation between electrical heterogeneity and ventricular energetics. Although there are numerous in vivo and in vitro studies on the electrical heterogeneity within the ventricular myocardium, not much attention has been directed to its correlation to cardiovascular mechanics, because of difficulties in simultaneously observing and analyzing multiple spatial scales (the cell, the organ, and the system). We performed simulations with two cardiovascular simulation models, one which uses different myocardial cell models for the epicardial, endocardial, and mid-myocardial cells, and another which uses a homogeneous model throughout the entire myocardium. The epicardial, endocardial, and midmyocardial cell models were created by parametrically tuning a homogenous cell model. From the cardiovascular simulation we obtained pressure-volume loops which were used to calculate cardiovascular energetic efficiency and myocardial contractility. We found that energetic efficiency is higher in the electrically heterogeneous model.
No takes yet. Share an insight, caveat, or question.
Hasegawa et al. (2013) studied this question. Electrically heterogeneous model vs. Homogeneous model was evaluated on Cardiovascular energetic efficiency and myocardial contractility. Cardiovascular simulation demonstrated that energetic efficiency is higher in an electrically heterogeneous ventricular model compared to a homogeneous model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: