Key result
A 17-year-old patient with an implanted left ventricular assist device died 21 months post-implantation due to an unexpected fatal complication of mesangioproliferative glomerulonephritis with extracapillary crescents.
Case Report (n=1)
No
Mesangioproliferative glomerulonephritis with extracapillary crescents can be a fatal complication in patients with LVAD implants, potentially involving CD44-mediated fibrogenesis.
Answers are grounded in this paper and cite their sources.
Raises caution for rare fatal glomerulonephritis post-LVAD; leaves open CD44-mediated mechanisms for targeted investigation.
The continuous flow left ventricular assist device (cf-LVAD) is the life-saving solution for patients with end-stage global heart failure. We present the case of a young patient with biventricular dilated cardiomyopathy, who had a cf-LVAD implantation and died as result of progressive renal failure. In the first year after implantation, he suffered repeated strokes and episodes of pneumonia with Klebsiella pneumoniae and Escherichia coli. The patient had hypertension, which was kept under control with angiotensin-converting enzyme (ACE) inhibitors and beta-blockers. After multiple bleeding episodes, the patient died at 21 months after the LVAD implant. At autopsy, parenchymatous brain hemorrhage was found to be associated with pulmonary hemorrhages. The unexpected features related to mesangioproliferative and extracapillary glomerulonephritis, with focal glomerulosclerosis. The proliferated parietal cells of Bowman's capsule proved to express cluster of differentiation 44 (CD44), whereas remnant podocytes and mesangial cells showed Wilms tumor 1 (WT1) positivity. Since CD44 might be involved in fibrogenesis, but ACE inhibitors can exert a protective role against glomerular deterioration, we performed a synthesis of literature data which enabled us to propose a hypothesis with a potential clinical impact. We conclude that, in patients with LVAD implants, high blood pressure and high serum level of angiotensin II, the association between ACE inhibitors and anti-CD44 agents might exert glomerular protection and increase the survival time. Experimental studies are necessary to support our hypothesis and to explain the mechanism of possible glomerulopathy installed after LVAD implant.
No takes yet. Share an insight, caveat, or question.
Opriş et al. (2020) conducted a case report in Dilated cardiomyopathy with left ventricular assist device (n=1). Continuous flow left ventricular assist device (cf-LVAD) was evaluated on Autopsy findings and cause of death. A 17-year-old patient with an implanted left ventricular assist device died 21 months post-implantation due to an unexpected fatal complication of mesangioproliferative glomerulonephritis with extracapillary crescents.
Synapse has enriched 10 related papers. Consider them for comparative context: