Key result
Biophen DiXaI showed a strong linear correlation with spiked rivaroxaban concentrations, indicating its utility for monitoring anticoagulation activity and evaluating bleeding risk.
Why the study?
How do routine coagulation assays correlate with rivaroxaban concentrations and its bleeding risk?
Observational
How do routine coagulation assays correlate with rivaroxaban concentrations and its bleeding risk?
Biophen DiXaI can be used as a quantitative method to monitor the anticoagulation activity of rivaroxaban, while PT (Thrombosis S) can serve as a rough monitoring method.
Answers are grounded in this paper and cite their sources.
Supports Biophen DiXaI evaluation for rivaroxaban monitoring in research; leaves open clinical utility pending patient studies.
BACKGROUND: The aims of this study were to investigate the effects of rivaroxaban on routine coagulation assays using our local, widely available, reagents and to study the relationship between sensitive coagulation assays and bleeding risk caused by rivaroxaban. METHODS: Prothrombin time (PT), activated partial thromboplastin time (APTT) and anti-factor Xa (FXa) chromogenic assays (Biophen DiXaI) and inhibition of FXa activity were performed in normal pooled plasma (NPP) spiked with rivaroxaban and plasma samples from patients treated with rivaroxaban. RESULTS: In vitro, the linear correlation coefficient of measured concentrations of rivaroxaban, by Biophen DiXaI, and spiked concentrations of rivaroxaban was 0.99. PT and APTT showed good linear correlation with rivaroxaban concentrations, while other assays showed poor correlation. In vivo, PT showed a moderate linear correlation with rivaroxaban concentrations while APTT had a weak correlation with rivaroxaban concentrations. In vitro and in vivo, the rivaroxaban concentrations, measured by Biophen DiXaI, always showed good correlation with the inhibition of FXa activity, and PT values showed moderate correlation with the inhibition of FXa activity. CONCLUSIONS: Biophen DiXaI can be considered as a quantitative method to monitor the anticoagulation activity of rivaroxaban, and could be used to evaluate bleeding risk caused by rivaroxaban. The PT reagent (Thrombosis S) could be considered as a rough method to monitor the anticoagulation activity of rivaroxaban and evaluate bleeding risk caused by rivaroxaban.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2016) conducted an observational in Patients treated with rivaroxaban. Rivaroxaban was evaluated on Correlation between measured and spiked concentrations of rivaroxaban (correlation coefficient 0.99). Biophen DiXaI showed a strong linear correlation with spiked rivaroxaban concentrations, indicating its utility for monitoring anticoagulation activity and evaluating bleeding risk.