Why the study?
The 2-year clinical safety and hemodynamic outcomes of the novel Cingular bovine pericardial bioprosthesis needed to be evaluated.
Does the Cingular bovine pericardial bioprosthesis provide safe clinical and hemodynamic outcomes in patients requiring aortic or mitral valve replacement?
Does the Cingular bovine pericardial bioprosthesis provide safe clinical and hemodynamic outcomes in patients requiring aortic or mitral valve replacement?
The Cingular bovine pericardial valve demonstrated favorable clinical safety and stable hemodynamic performance at 2 years in patients requiring aortic or mitral valve replacement.
Answers are grounded in this paper and cite their sources.
Supports short-term safety of Cingular bioprosthesis; leaves open long-term durability and comparative effectiveness.
Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients were implanted with the Cingular bovine pericardial valve at five sites in China. The clinical outcomes and hemodynamic performance were assessed through a 2-year follow-up. Clinical safety events were reviewed by an independent clinical events committee, and echocardiographic data were assessed by an independent core laboratory. Results: The mean age was 66.9 ± 4.9 years. The 2-year survival rate was 96.4%. A complete 2-year clinical follow-up was achieved in 189 of 190 survivors. No case of structural valve deterioration, major perivalvular leak, prosthetic valve endocarditis, or valve-related reoperation was seen. For the aortic valve, the mean pressure gradient observed was 12.5 ± 4.0 mm Hg, and the effective orifice area (EOA) was 2.0 ± 0.3 cm 2 . For the smaller size aortic valves, 19 mm and 21 mm, respective mean EOA values of 1.7 ± 0.2 cm 2 and 1.8 ± 0.2 cm 2 were found. The values for mean pressure gradient and mean EOA for mitral bioprostheses were 4.0 ± 1.4 mm Hg and 2.2 ± 0.3 cm 2 , respectively. There was no significant change between 1-year and 2-year hemodynamic performance. Conclusions: The Cingular bovine pericardial valve showed favorable clinical safety and hemodynamic outcomes over a 2-year follow-up. Further follow-up is required to validate the long-term durability.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: