Key result
TWA Identifier successfully quantified T-wave alternans from a 24-hour ECG in a hemodialysis patient, showing elevated values ranging from 35 μV to 78 μV, particularly during the session.
Why the study?
Sudden cardiac death risk is increased in hemodialysis patients, and the study aimed to evaluate TWA Identifier as a software application for cardiac risk self-monitoring during hemodialysis.
Can the TWA Identifier software application monitor T-wave alternans for cardiac risk assessment in a hemodialysis patient?
Case Report (n=1)
Can the TWA Identifier software application monitor T-wave alternans for cardiac risk assessment in a hemodialysis patient?
The TWA Identifier software successfully quantified elevated T-wave alternans during hemodialysis, demonstrating its potential for real-time cardiac risk self-monitoring.
Answers are grounded in this paper and cite their sources.
TWA monitoring feasible in one hemodialysis case; leaves open utility for cardiac risk stratification.
Rate of sudden cardiac death (SCD) is increased in hemodialysis (HD) patients. Cardiac risk can be evaluated in terms of electrocardiographic (ECG) T-wave alternans (TWA). Aim of the present study was to propose TWA Identifier as a software application for cardiac risk self-monitoring based on the TWA index, and to test it on a patient while performing a HD session. TWA Identifier can be installed on any portable device and may analyze real-time ECG data acquired by wearable sensors. Core of TWA Identifier is the well-established heart-rate adaptive match filter method for TWA identification. TWA Identifier quantified TWA from a continuous 24-hours ECG acquired using a wearable Holter ECG recorder in a HD patient during a HD day. The recording was divided into macro-time periods, one prior, one contemporary and two following the HD session. On average, TWA values were higher than normal, ranged from 35 μV to 78 μV, and were particularly high during the HD session, while decreased afterwards. Thus, the HD patient was at increased SCD risk, especially during the treatment. In conclusion, TWA Identifier represents a useful tool for real-time cardiac risk self-monitoring during HD.
No takes yet. Share an insight, caveat, or question.
Leoni et al. (2019) conducted a case report in Hemodialysis (n=1). TWA Identifier software was evaluated on T-wave alternans (TWA) values. TWA Identifier successfully quantified T-wave alternans from a 24-hour ECG in a hemodialysis patient, showing elevated values ranging from 35 μV to 78 μV, particularly during the session.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: