Key result
A single-slice computed tomography measurement of renal sinus fat was highly correlated with volumetric measurement and demonstrated high intra- and inter-reader reproducibility.
Cross-Sectional (n=92)
No
A single-slice MDCT measurement of renal sinus fat is highly reproducible and correlates well with volumetric measurements and systemic adiposity, providing a feasible imaging biomarker for community-based studies.
Answers are grounded in this paper and cite their sources.
Single-slice CT enables feasible renal sinus fat assessment in community cohorts; leaves open its prognostic utility in prospective studies.
BACKGROUND: Renal sinus fat may mediate obesity-related vascular disease, although this fat depot has not been assessed in a community-based sample. We sought to develop a protocol to quantify renal sinus fat accumulation using multi-detector computed tomography (MDCT). METHODS: Protocol development was performed in participants in the Framingham Offspring cohort who underwent MDCT. Volumetric renal sinus fat was measured separately within the right and left kidneys, and renal sinus fat area within a single MDCT scan slice was measured in the right kidney. Due to the high correlation of volumetric and single-slice renal sinus fat in the right kidney (Pearson correlation [r] = 0.85, p < 0.0001), we optimized a single-slice protocol to capture renal sinus fat in the right kidney alone. Pearson correlation coefficients were used to compare to assess the correlation of volumetric and single-slice renal sinus fat in the right kidney with other measures of adiposity. Inter- and intra-reader reproducibility was assessed using intra-class correlation coefficients. RESULTS: Single-slice measurements were obtained in 92 participants (mean age 60 years, 49% women, median renal sinus fat 0.43 cm2). Intra- and inter-reader intra-class correlation coefficients were 0.93 and 0.86, respectively. Single-slice renal sinus fat was correlated with body mass index (r = 0.35, p = 0.0006), waist circumference (r = 0.31, p = 0.003), and abdominal visceral fat (r = 0.48, p < 0.0001). Similar correlations were observed for volumetric renal sinus fat in the right kidney. CONCLUSIONS: Measuring renal sinus fat is feasible and reproducible using MDCT scans in a community-based sample.
No takes yet. Share an insight, caveat, or question.
Foster et al. (2011) conducted a cross-sectional in Healthy (Community-based sample) (n=92). Single-slice MDCT measurement of renal sinus fat vs. Volumetric MDCT measurement was evaluated on Correlation between single-slice and volumetric renal sinus fat in the right kidney (r = 0.85, p=<0.0001). A single-slice computed tomography measurement of renal sinus fat was highly correlated with volumetric measurement and demonstrated high intra- and inter-reader reproducibility.
Synapse has enriched 10 related papers. Consider them for comparative context: