Key result
A statistical bicoherence thresholding procedure identified two types of very-high frequency peaks in heart transplant patients, one reflecting nonlinear cardiac-respiratory coupling.
A novel bicoherence thresholding procedure successfully distinguished true phase coupling from spurious peaks in the cardiovascular signals of heart transplant patients, revealing a potentially new compensatory mechanism.
Hypothesis-generating for compensatory mechanisms in heart transplant patients; leaves open clinical utility of bicoherence analysis.
Following heart transplant (HT), the patient's heart functions under complete cardiac denervation. As a result, the variability in physiologic signals is extremely reduced. We have previously reported that in addition to the typical spectral components (of very low amplitude), part of the HT patients (above 50%) demonstrated unexpected additional peaks in their heart rate and blood pressure spectra. These peaks may be a result of the development of compensatory mechanism induced by loss of parasympathetic control, or of increased importance of nonlinear control interactions. It is important to quantify these strange, unexpected very-high frequency (VHF) peaks, to understand their origin and their contribution to cardiac control in transplant patients. In this paper, we chose to examine these VHF peaks by applying the bicoherence approach. The reduced signal to noise ratio, occurring in these patients, results, however, in an extremely noisy bicoherence. We, therefore, developed several statistical tools in order to distinguish between "true" bicoherence peaks (reflecting true phase coupling) and spurious peaks. The outcome of these methods was an efficient and sensitive bicoherence thresholding procedure, able to identify most of the spurious peaks. Applying these tools to the bicoherence of cardiovascular signals which display VHF peaks, revealed several significant bicoherence peaks. Interestingly, these peaks consisted of two different types. The first type of VHF peaks simply reflects nonlinear cardiac-respiratory coupling, imposed by nonsinusoidal breathing. The second type, however, is clearly not induced by the respiratory system. We believe that these type-2 VHF peaks reflect the evolution of a new, yet unexplained, compensatory mechanism.
No takes yet. Share an insight, caveat, or question.
Pinhas et al. (2004) studied Heart transplant. Bicoherence analysis with statistical thresholding was evaluated on Identification of true bicoherence peaks. A statistical bicoherence thresholding procedure identified two types of very-high frequency peaks in heart transplant patients, one reflecting nonlinear cardiac-respiratory coupling.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: