Key result
Night-peak RVOT arrhythmias linked to ~2.9-fold higher post-ablation recurrence vs nondiurnal patterns.
Why the study?
Does diurnal variation type predict the recurrence rate of ventricular arrhythmias after catheter ablation in patients with idiopathic RVOT VA?
Cohort (n=62)
No
Does diurnal variation type predict the recurrence rate of ventricular arrhythmias after catheter ablation in patients with idiopathic RVOT VA?
Patients with idiopathic RVOT ventricular arrhythmias who exhibit nocturnal diurnal variation have a significantly higher rate of arrhythmia recurrence following catheter ablation.
Answers are grounded in this paper and cite their sources.
Nocturnal RVOT VA pattern was associated with higher post-ablation recurrence; hypothesis-generating for risk stratification and requires prospective validation.
Diurnal variations in ventricular tachyarrhythmias (VAs) have been demonstrated in idiopathic arrhythmogenic heart disease. The electrophysiological characteristics of diurnal variations in idiopathic right ventricular outflow tract (RVOT) VA have not previously been elucidated. Sixty-two consecutive patients undergoing catheter ablation for idiopathic RVOT VA (mean age: 42.8 ± 12.3 years, 35 females) were enrolled. The diurnal variation type (group 1, n = 36) was defined as those patients who had most ventricular premature contractions (VPCs) during the night hours by preprocedure Holter recordings. Group 2 (n = 26) was defined as those patients who did not have significant VPC variations. The baseline characteristics and electrophysiological properties were collected and analyzed, and the rates of recurrence after catheter ablation were compared between the 2 groups. In this study, heart rate variability analysis demonstrated lower low frequency/high frequency ratios in group 1 than in group 2 (3.95 ± 3.08 vs 6.26 ± 5.33; P = 0.042). There were no significant differences in baseline characteristics, echocardiography and electrophysiological characteristics between the 2 groups. During a mean follow-up period of 13.5 ± 11.0 months, a total of 16 patients had VA recurrences, including 13 patients from group 1 and 3 patients from group 2 (36.1% vs 12.5%, P = 0.039). This study demonstrated the effect of the autonomic nervous system in idiopathic RVOT VAs and that the diurnal variation type leads to a higher recurrence rate after catheter ablation.
No takes yet. Share an insight, caveat, or question.
Jhuo et al. (2017) conducted a cohort in Idiopathic right ventricular outflow tract ventricular arrhythmia (n=62). Diurnal variation type (night-time peak of ventricular premature complexes) vs. Nondiurnal variation type was evaluated on Ventricular tachyarrhythmia (VA) recurrence after catheter ablation (p=0.039). Patients with a diurnal variation type (night-time peak) of right ventricular outflow tract arrhythmias had a higher rate of ventricular tachyarrhythmia recurrence after catheter ablation compared to those with a nondiurnal pattern.
Synapse has enriched 10 related papers. Consider them for comparative context: