Key result
CF-sensing ablation is linked to ~15 minutes shorter procedure times vs conventional catheters in pediatrics.
Why the study?
Ablation of septal accessory pathways in pediatric patients presents significant challenges due to close proximity to the AV node, warranting evaluation of contact force-sensing technology with a conservative force strategy.
Does contact force-sensing technology with a conservative force strategy improve procedural efficiency and safety compared to conventional irrigated catheters in pediatric patients undergoing ablation for septal accessory pathways?
Cohort (n=157)
Does contact force-sensing technology with a conservative force strategy improve procedural efficiency and safety compared to conventional irrigated catheters in pediatric patients undergoing ablation for septal accessory pathways?
Integrating contact force technology with a conservative force strategy (5-12 g) enhances procedural efficiency in pediatric septal accessory pathway ablation without compromising safety.
Answers are grounded in this paper and cite their sources.
May shorten pediatric septal ablation times; hypothesis-generating, needs prospective randomized confirmation.
Introduction The ablation of septal accessory pathways (APs) in pediatric patients presents significant challenges owing to the close proximity of the atrioventricular (AV) node. Our objective was to assess the influence of contact force (CF)–sensing technology combined with a “conservative force” strategy on procedural efficiency and safety within this high‐risk demographic. Methods We retrospectively analyzed 157 pediatric patients who underwent radiofrequency (RF) ablation for septal APs (anteroseptal, midseptal, or posteroseptal). Patients were divided into two groups: the CF group ( n = 77), utilizing a target force of 5–12 g, and the non‐CF group ( n = 80), using conventional irrigated catheters. Results The CF group achieved significantly shorter total procedure times (65.0 vs. 80.0 min; p = 0.029) and reduced total RF application times (78.0 vs. 105.0 s; p = 0.047) compared to the non‐CF group. In the CF group, the median CF was 10.0 g, and the median RF power was significantly lower than in the non‐CF group (25 W vs. 30 W; p = 0.003). Subgroup analysis revealed a significant gain in efficiency for posteroseptal (PS) pathways , whereas anteroseptal (AS) pathways required longer procedure times in the CF era due to safety‐driven force titration (105.0 vs. 70.0 min; p = 0.012). Acute success rates (98.7% vs. 93.8%; p = 0.210) and recurrence rates (5.2% vs. 11.3%; p = 0.277) were comparable between the groups. No permanent AV block or major complications occurred in either cohort. Conclusion Integrating CF technology with a conservative force strategy (5–12 g) enhances procedural efficiency in pediatric septal AP ablation without compromising safety. While it streamlines the workflow for most septal locations, the AS region requires more meticulous titration, and the midseptal (MS) region remains the most prone to recurrence.
No takes yet. Share an insight, caveat, or question.
Öksüz et al. (2026) conducted a cohort in Septal accessory pathways (n=157). Contact force-sensing technology vs. Conventional irrigated catheters (non-CF) was evaluated on Total procedure times (minutes) (p=0.029). Contact force-sensing technology with a conservative force strategy reduced total procedure times compared to conventional catheters in pediatric patients.
Synapse has enriched 10 related papers. Consider them for comparative context: