Key result
Contact force ablation yields similar acute success to traditional RF for pediatric accessory pathways.
Why the study?
Data evaluating contact force catheter use for accessory pathway ablation or in pediatric patients were limited.
Does contact force ablation improve procedure times, number of lesions, and clinical outcomes compared to traditional radiofrequency ablation in pediatric patients with accessory pathways?
Cohort (n=112)
No
Does contact force ablation improve procedure times, number of lesions, and clinical outcomes compared to traditional radiofrequency ablation in pediatric patients with accessory pathways?
Contact force ablation yields comparable procedural times, lesion numbers, and clinical outcomes to traditional radiofrequency ablation for accessory pathways in pediatric patients.
Answers are grounded in this paper and cite their sources.
Comparable acute success supports either approach in pediatric accessory pathways; leaves open randomized confirmation of long-term outcomes.
INTRODUCTION: Contact force (CF) catheters provide feedback confirming adequate tissue contact for optimal lesion size and minimal complications. CF ablation catheters have resulted in decreased procedure times and improved outcomes for ablation of atrial fibrillation in adults. There is limited data evaluating CF use for accessory pathway (AP) ablation or in pediatric patients. The aim of our study was to compare a cohort who underwent AP ablation with a CF catheter to historical controls, evaluating for differences in procedure times, number of lesions, and outcomes. METHODS: A retrospective chart review of CF ablation cases at Children's Wisconsin performed between June 2015 to April 2018 was compared to a historical control cohort of traditional radiofrequency (RF) ablations between June 2012 and June 2015. 43 patients with APs underwent 49 CF ablation procedures (18 males, 13.6 ± 3 years old) and a control cohort consisted of 77 procedures in 69 patients (38 males, 12.4 ± 4 years). RESULTS: The groups did not differ significantly on procedure time (CF 2.01 ± 0.48 h, control 1.53 ± 0.48 h, p = .37), or total lesions administered (CF and control 7 ± 6 lesions, p = .89). CF cases showed a trend toward improvement in acute success (98% CF, 90% controls, p = .15) though with increased recurrence compared to controls (13% CF, 4.3% controls, p = .16), neither being statistically significant. CONCLUSION: Our study suggests that ablation outcomes using CF are comparable to traditional RF ablation in pediatric patients with APs.
No takes yet. Share an insight, caveat, or question.
Pook et al. (2020) conducted a cohort in Accessory pathways (n=112). Contact force (CF) ablation vs. Traditional radiofrequency (RF) ablation was evaluated on Acute success (p=0.15). Contact force ablation for accessory pathways in pediatric patients resulted in similar acute success compared to traditional radiofrequency ablation.
Synapse has enriched 10 related papers. Consider them for comparative context: