Key result
Simultaneous valve-in-valve TAVR and LAAC under cerebral protection succeeds without neurologic complications in 1 patient.
Why the study?
Persistent left atrial appendage thrombus complicates structural intervention when anticoagulation is limited by bleeding risk.
Does simultaneous valve-in-valve TAVR and left atrial appendage closure with cerebral embolic protection prevent neurologic complications in a high-risk patient with severe bioprosthetic aortic stenosis and persistent left atrial appendage thrombus?
Case Report (n=1)
Does simultaneous valve-in-valve TAVR and left atrial appendage closure with cerebral embolic protection prevent neurologic complications in a high-risk patient with severe bioprosthetic aortic stenosis and persistent left atrial appendage thrombus?
Simultaneous valve-in-valve TAVR and LAA closure with cerebral embolic protection is a feasible and potentially safe strategy for high-risk patients with severe bioprosthetic aortic stenosis, persistent LAA thrombus, and high bleeding risk.
Answers are grounded in this paper and cite their sources.
May offer option for persistent LAA thrombus with high bleeding risk; hypothesis-generating and requires prospective validation.
BACKGROUND: Persistent left atrial appendage thrombus complicates structural intervention when anticoagulation is limited by bleeding risk. CASE SUMMARY: A 74-year-old man with prior surgical aortic and mitral bioprostheses presented with heart failure from severe bioprosthetic aortic stenosis and persistent left atrial appendage thrombus despite 6 months of anticoagulation. Because of recent gastrointestinal bleeding and progressive valve obstruction, the heart team selected a single-session strategy using Sentinel cerebral embolic protection. Valve-in-valve transcatheter aortic valve replacement was performed first, followed by bioprosthetic valve fracture confirmed by balloon pressure drop, waist release, and gradient reduction. Left atrial appendage closure was then performed with a Watchman FLX Pro device, trapping residual thrombus. Retrieved cerebral protection filters contained thrombotic debris, and the patient recovered without neurologic complications. DISCUSSION: In selected high-risk patients, simultaneous valve intervention and thrombus-exclusion left atrial appendage closure under cerebral protection may reduce cumulative procedural and anticoagulation-related risks.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2026) conducted a case report in Severe bioprosthetic aortic stenosis and persistent left atrial appendage thrombus (n=1). Simultaneous valve-in-valve TAVR with bioprosthetic valve fracture and left atrial appendage closure was evaluated on Neurologic complications. Simultaneous valve-in-valve TAVR and left atrial appendage closure under cerebral protection was successfully performed without neurologic complications in 1 patient with persistent LA thrombus.