Key result
A 10-variable clinical risk score stratified the risk of in-hospital complications after ICD implantation, with event rates ranging from 0.6% for scores ≤5 to 8.4% for scores ≥19.
Why the study?
Can a simple risk score identify patients at high and low risk of acute procedural complications or death after ICD implantation?
Observational (n=268,701)
Yes
Can a simple risk score identify patients at high and low risk of acute procedural complications or death after ICD implantation?
Answers are grounded in this paper and cite their sources.
A simple 10-variable risk score can effectively stratify patients by their risk of acute in-hospital complications or death following ICD implantation, aiding in patient selection and post-procedure care planning.
BACKGROUND: Patients undergoing implantable cardioverter-defibrillator (ICD) implantation are at risk of postprocedural complications. However, we do not have a risk stratification schema to identify patients at high and low risk of adverse events. METHODS AND RESULTS: We analyzed data from 268 701 ICD implants submitted to the ICD Registry and developed logistic regression models to identify variables most strongly associated with the risk of acute complications and/or in-hospital death. Overall, 3.2% of the population experienced an adverse event. A simple risk score consisting of 10 readily available variables successfully identified patients at high and low risk of complications. The variables included in the score and assigned points included: age ≥ 70 years (1 point), female (2 points), New York Heart Association class III (1 point) or IV (3 points), atrial fibrillation (1 point), prior valve surgery (3 points), chronic lung disease (2 points), blood urea nitrogen >30 (2 points), reimplantation for reasons other than battery change (6 points), ICD type dual chamber (2 points) or biventricular (4 points), and nonelective ICD implant (3 points). The risk of any in-hospital complication increased from 0.6% among patients with a score of ≤ 5 (8.4% of the population) to 8.4% among patients with ≥ 19 risk points (3.9% of the population). CONCLUSIONS: A simple risk score consisting of readily available clinical variables can identify high- and low-risk subsets of patients undergoing ICD implantation. This information can guide the physician in patient selection and determining the intensity of care required post procedure.
No takes yet. Share an insight, caveat, or question.
Haines et al. (2011) conducted an observational in Implantable cardioverter-defibrillator (ICD) implantation (n=268,701). 10-variable clinical risk score vs. Low risk score (≤ 5) was evaluated on Acute complications and/or in-hospital death. A 10-variable clinical risk score stratified the risk of in-hospital complications after ICD implantation, with event rates ranging from 0.6% for scores ≤5 to 8.4% for scores ≥19.