Key result
A 10-variable clinical risk score stratified the risk of in-hospital complications after ICD implantation, with event rates ranging from 0.6% for scores ≤5 to 8.4% for scores ≥19.
Why the study?
Can a simple risk score identify patients at high and low risk of acute procedural complications or death after ICD implantation?
Population
268,701 ICD implants submitted to the ICD Registry
Design
Cohort
Follow-up
in-hospital
Authors
Loading...
May guide pre-ICD risk assessment and monitoring; leaves open prospective validation and outcome impact.
Observational (n=268,701)
Yes
Can a simple risk score identify patients at high and low risk of acute procedural complications or death after ICD implantation?
Absolute Event Rate: 8.4% vs 0.6%
A simple 10-variable risk score can effectively stratify patients by their risk of acute in-hospital complications or death following ICD implantation, aiding in patient selection and post-procedure care planning.
Haines et al. (2011) conducted an observational in Implantable cardioverter-defibrillator (ICD) implantation (n=268,701). 10-variable clinical risk score vs. Low risk score (≤ 5) was evaluated on Acute complications and/or in-hospital death. A 10-variable clinical risk score stratified the risk of in-hospital complications after ICD implantation, with event rates ranging from 0.6% for scores ≤5 to 8.4% for scores ≥19.