Key result
The AAACC risk score predicted 1-year mortality after ICD implantation with an area under the curve of 0.71 (95% CI 0.66-0.76), with risk increasing from 1% for 0 points to 12.5% for >4 points.
Why the study?
Does the AAACC risk score accurately predict 1-year mortality in patients undergoing ICD or CRT-D implantation?
Population
2,617 patients from the prospective Israeli ICD Registry who underwent implantable cardioverter…
Design
Cohort
Follow-up
1 year
Authors
Loading...
AAACC score may aid post-ICD risk stratification; hypothesis-generating and requires prospective validation before clinical adoption.
Cohort (n=2,617)
Yes
Does the AAACC risk score accurately predict 1-year mortality in patients undergoing ICD or CRT-D implantation?
Effect estimate: AUC 0.71 (95% CI 0.66-0.76)
The AAACC risk score is a simple clinical tool that can identify patients at high risk of 1-year mortality after ICD implantation, potentially aiding in patient selection by identifying those who may not survive long enough to benefit from the device.
Nevzorov et al. (2018) conducted a cohort in Implantable cardioverter defibrillator (ICD) or CRT-D implantation (n=2,617). AAACC risk score vs. Lower risk score was evaluated on 1-year mortality (AUC 0.71, 95% CI 0.66-0.76). The AAACC risk score predicted 1-year mortality after ICD implantation with an area under the curve of 0.71 (95% CI 0.66-0.76), with risk increasing from 1% for 0 points to 12.5% for >4 points.