Key result
The AAACC risk score predicted 1-year mortality after ICD implantation with an area under the curve of 0.71, with risk increasing from 1% for 0 points to 12.5% for >4 points.
Why the study?
Does the AAACC risk score accurately predict 1-year mortality in patients undergoing ICD or CRT-D implantation?
Cohort (n=2,617)
Yes
Does the AAACC risk score accurately predict 1-year mortality in patients undergoing ICD or CRT-D implantation?
The AAACC risk score is a simple clinical tool that can identify patients at high risk of 1-year mortality after ICD implantation, potentially aiding in patient selection by identifying those who may not survive long enough to benefit from the device.
Answers are grounded in this paper and cite their sources.
AAACC score may aid post-ICD risk stratification; hypothesis-generating and requires prospective validation before clinical adoption.
INTRODUCTION: Life expectancy of less than 1 year is usually a contraindication for implantable cardioverter defibrillator (ICD) implantation. The aim was to identify patients at risk of death during the first year after implantation. METHODS AND RESULTS: Data were derived from a prospective Israeli ICD Registry. Two groups of patients were compared, those who died and those who were alive 1 year after ICD implantation. Factors associated with 1-year mortality were identified on a derivation cohort. A risk score was established and validated. A total of 2617 patients have completed 1 year of follow-up after ICD or cardiac resynchronization therapy defibrillator (CRT-D) implantation. Age greater than 75 years (hazard ratio [HR], 2.7; 95% confidence interval [95% CI], 1.6 to 4.4), atrial fibrillation (AF; HR, 1.9; 95% CI, 1.12 to 3.17), chronic lung disease (HR, 2.0; 95% CI, 1.1 to 3.76), anemia (HR, 2.3; 95% CI, 1.3 to 3.93) and chronic renal failure (CRF; HR, 3.4; 95% CI, 1.74 to 6.6) were independent risk factors for 1-year mortality. We propose a simple AAACC ("triple A double C") score for prediction of 1-year mortality after ICD implantation: Age greater than 75 years (3 points(pts)), anemia (2 pts), AF (1 pt), CRF (3 pts) and chronic lung disease (1 pt). Mortality risk increased with rising number of points (from 1% with 0 pts to 12.5% with >4 pts). The risk score was evaluated with receiver operating characteristic curve and the area under the curve of the validation curve is 0.71 (95% CI, 0.66 to 0.76). CONCLUSIONS: Age greater than 75, AF, chronic lung disease, anemia, and CRF were independent risk factors for 1-year mortality. AAACC risk score identifies patients at high risk of death during 1 year after ICD implantation.
No takes yet. Share an insight, caveat, or question.
Nevzorov et al. (2018) conducted a cohort in Implantable cardioverter defibrillator (ICD) or CRT-D implantation (n=2,617). AAACC risk score vs. Lower risk score was evaluated on 1-year mortality (AUC 0.71, 95% CI 0.66-0.76). The AAACC risk score predicted 1-year mortality after ICD implantation with an area under the curve of 0.71, with risk increasing from 1% for 0 points to 12.5% for >4 points.
Synapse has enriched 10 related papers. Consider them for comparative context: