Key result
Pre-implant serum urea >9.28 mmol/L independently predicted mortality (HR 2.12) and none of the four complex clinical risk scoring systems significantly outperformed it for predicting 1-year or 3-year mortality.
Why the study?
Do complex risk scoring systems outperform serum urea in predicting short-term mortality in patients undergoing first-time ICD implantation?
Observational (n=406)
No
Do complex risk scoring systems outperform serum urea in predicting short-term mortality in patients undergoing first-time ICD implantation?
Complex risk scoring systems for predicting short-term mortality after ICD implantation do not significantly outperform a single measurement of serum urea.
Answers are grounded in this paper and cite their sources.
May help identify high-risk ICD recipients unlikely to benefit; leaves open need for prospective validation of scoring systems.
PURPOSE: Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. METHODS: We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. RESULTS: Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P < 0.0001); however, none outperformed urea for the prediction of 1- or 3-year mortality. CONCLUSIONS: Using published scoring systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.
No takes yet. Share an insight, caveat, or question.
Kaura et al. (2017) conducted an observational in Patients undergoing first-time ICD implantation (n=406). Serum urea >9.28 mmol/L vs. Serum urea ≤9.28 mmol/L was evaluated on All-cause mortality (HR 2.123, 95% CI 1.238-3.643, p=0.006). Pre-implant serum urea >9.28 mmol/L independently predicted mortality (HR 2.12) and none of the four complex clinical risk scoring systems significantly outperformed it for predicting 1-year or 3-year mortality.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: