Key result
In patients with hemodynamically not tolerated ventricular tachycardia and LVEF >35%, the overall recurrence rate of VT was 14.3%, with all recurrences being hemodynamically tolerated.
Why the study?
The benefit of ICD implantation in patients with hemodynamically not tolerated VT and midrange reduced to normal ejection fraction (LVEF >35%) is unclear.
What is the rate of VT recurrence and the role of ICD implantation in patients with hemodynamically not tolerated VT and LVEF >35%?
Observational (n=42)
No
What is the rate of VT recurrence and the role of ICD implantation in patients with hemodynamically not tolerated VT and LVEF >35%?
Answers are grounded in this paper and cite their sources.
Patients with hemodynamically not tolerated VT and LVEF >35% have a relatively low and nonfatal recurrence rate, suggesting that ablation success, LVEF, and severity of hemodynamic compromise should guide ICD implantation decisions.
INTRODUCTION: The benefit of implantable cardioverter-defibrillator (ICD) implantation in patients with hemodynamically not tolerated ventricular tachycardia (VT) and midrange reduced to normal ejection fraction (LVEF >35%) is currently unclear. The purpose of this study was to investigate follow-up after hemodynamically not tolerated VT in patients with LVEF >35%. In addition, we aimed to find possible predictive factors to identify who will benefit from ICD implantation. METHODS: In a retrospective single-centre case series, all patients with hemodynamically not tolerated VT and LVEF >35% that underwent electrophysiological study (EPS) and/or radiofrequency VT ablation were included. RESULTS: Forty-two patients (5 women, median age 68 years) with hemodynamically not tolerated VT and LVEF >35% underwent EPS. VT ablation was performed in thirty-one patients, which was considered successful in twenty-three patients. Nineteen patients had an ICD at discharge while 23 patients were discharged without an ICD. The severity of hemodynamic compromise, LVEF and ablation success played an important role in the decision-making for ICD implantation. Six patients (14.3%) had recurrence of VT, all hemodynamically tolerated. CONCLUSIONS: In this small case series, patients with hemodynamically not tolerated VT and LVEF >35% had a relatively low recurrence rate and all recurrences were nonfatal. Based on our results, we hypothesize that the severity of hemodynamic compromise, LVEF and ablation success might modify the risk for VA recurrence. A prospective study to determine the prognostic value of these factors in patients with hemodynamically not tolerated VT and LVEF >35% is necessary.
No takes yet. Share an insight, caveat, or question.
Groeneveld et al. (2020) conducted an observational in Hemodynamically not tolerated ventricular tachycardia with LVEF >35% (n=42). Implantable cardioverter-defibrillator (ICD) vs. No ICD was evaluated on Recurrence of ventricular tachycardia. In patients with hemodynamically not tolerated ventricular tachycardia and LVEF >35%, the overall recurrence rate of VT was 14.3%, with all recurrences being hemodynamically tolerated.