Key result
Regional frame under-expansion of a 26-mm CoreValve impaired leaflet kinematics, reduced range of motion, and induced localized high-stress regions in experimental and computational simulations.
Why the study?
Regional stent underexpansion of transcatheter aortic valves has been linked to subclinical leaflet thrombosis, but its effects on leaflet kinematics and structural characteristics remained unclear.
Computational and experimental modeling demonstrates that regional under-expansion of transcatheter aortic valves increases mechanical stress and blood stasis, providing a mechanistic basis for subclinical leaflet thrombosis.
Supports closer monitoring for subclinical thrombosis in under-expanded TAVs; leaves open whether expansion optimization reduces events.
Subclinical leaflet thrombosis has been increasingly recognized following transcatheter aortic valve replacement (TAVR). Determining the risk factors is vital in preventing clinical leaflet thrombosis and ensuring long-term value durability. Clinical data have indicated that regional stent under-expansion of transcatheter aortic valves (TAVs), particularly self-expanding devices, may be associated with an increased risk of subclinical leaflet thrombosis. This study aimed to determine the effects of regional TAV frame under-expansion on leaflet kinematics, leaflet structural characteristics, and explore its impact on the likelihood of leaflet thrombosis. In this study, mild and moderate regional frame under-expansion of a 26-mm CoreValve were examined using experimental testing and computational simulations. The results indicated that regional TAV frame under-expansion impairs leaflet kinematics and reduces the range of motion in leaflets with an angle less than 120°. The reduced range of motion can increase blood stasis on the surface of the TAV leaflets. The results also demonstrated that regional frame under-expansion induced localized high-stress regions in the leaflets close to the fixed boundary edge. The increased mechanical stress can lead to accelerated tissue degeneration. The study improves our understanding of the effects of regional stent under-expansion in TAVR. Post-procedural balloon dilatation of self-expanding TAVs can potentially be advantageous in reducing leaflet distortion and normalizing leaflet stress distribution. Large-scale, prospective, and well-controlled studies are needed to further investigate regional TAV frame under-expansion effects on subclinical leaflet thrombosis and long-term valve durability.
No takes yet. Share an insight, caveat, or question.
Qiu et al. (2022) studied Subclinical leaflet thrombosis following transcatheter aortic valve replacement (TAVR). Regional frame under-expansion of a 26-mm CoreValve was evaluated on Leaflet kinematics, leaflet structural characteristics, and likelihood of leaflet thrombosis. Regional frame under-expansion of a 26-mm CoreValve impaired leaflet kinematics, reduced range of motion, and induced localized high-stress regions in experimental and computational simulations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: