Key result
Non-invasive RAP ≥10 mmHg linked to ~2.4-fold higher risk of death or heart failure hospitalization.
Why the study?
Does elevated right atrial pressure measured by near-infrared spectroscopy predict the risk of death or heart failure hospitalization in patients with chronic heart failure?
Observational (n=292)
No
Does elevated right atrial pressure measured by near-infrared spectroscopy predict the risk of death or heart failure hospitalization in patients with chronic heart failure?
Answers are grounded in this paper and cite their sources.
Non-invasive measurement of right atrial pressure by near-infrared spectroscopy identifies ambulatory heart failure patients with elevated congestion and a substantially higher risk of death or heart failure hospitalization.
AIMS: To assess the clinical value of measuring right atrial pressure (RAP) using near-infrared spectroscopy (NIRS) in patients with chronic heart failure (CHF). METHODS AND RESULTS: RAP was measured non-invasively using NIRS over the external jugular vein (Venus 1000, Mespere LifeSciences, Canada) in ambulatory patients with CHF enrolled in the Studies Investigating Co-morbidities Aggravating Heart Failure (SICA-HF) programme. Comparing 243 patients with CHF (mean age 71 years; mean left ventricular ejection fraction (LVEF) 45%, median NT-proBNP 788 ng/L) to 49 controls (NT-proBNP ≤125 ng/L), RAP was 7 [interquartile range (IQR) 4-11] mmHg vs. 4 (IQR 3-8) mmHg (P < 0.001). Those with RAP ≥10 mmHg (n = 75) were older, had more severe clinical congestion and renal dysfunction, higher plasma NT-proBNP, larger left atrial volume, higher systolic pulmonary pressure and were more often in atrial fibrillation but their LVEF was similar to patients with lower RAP. During a median follow-up of 595 (IQR: 492-714) days, 49 patients (20%) died or were hospitalized for worsening CHF. Compared with patients with RAP ≤5 mmHg, those with RAP ≥10 mmHg had a greater risk of an event (hazard ratio 2.38, 95% confidence interval 1.19-4.75, P = 0.014). RAP measured by NIRS predicted outcome, competing with NT-proBNP in multivariable models. CONCLUSIONS: Measuring RAP using NIRS identifies ambulatory patients with CHF who have more severe congestion and a worse outcome. The device might be a useful objective method of monitoring RAP, especially for those inexperienced in eliciting physical signs or when measurement of natriuretic peptides is not immediately available.
No takes yet. Share an insight, caveat, or question.
Pellicori et al. (2017) conducted an observational in Chronic heart failure (n=292). Elevated right atrial pressure (≥10 mmHg) measured by near-infrared spectroscopy vs. Normal right atrial pressure (≤5 mmHg) was evaluated on Composite of heart failure hospitalization or all-cause mortality (HR 2.38, 95% CI 1.19-4.75, p=0.014). Right atrial pressure ≥10 mmHg measured non-invasively by near-infrared spectroscopy was associated with a increased risk of death or heart failure hospitalization compared to ≤5 mmHg.
Synapse has enriched 10 related papers. Consider them for comparative context: