Key result
Mosaic pattern recognition captures ~79% of persistent AF driver regions, outperforming conventional low-voltage mapping.
Why the study?
Driver-targeted ablation is a potential adjunct to PVI in persistent AF, but identifying drivers remains challenging.
Does ablation guided by mosaic pattern recognition using optimized voltage thresholds improve driver identification and clinical outcomes in patients with persistent atrial fibrillation?
Cohort (n=254)
Yes
Does ablation guided by mosaic pattern recognition using optimized voltage thresholds improve driver identification and clinical outcomes in patients with persistent atrial fibrillation?
A mosaic pattern within the atrial voltage transition zone (0.16-0.61 mV) accurately identifies AF driver regions and may serve as a feasible adjunct to electrogram-guided mapping for persistent AF ablation.
Answers are grounded in this paper and cite their sources.
May aid voltage-based driver targeting in persistent AF ablation; hypothesis-generating pending randomized outcome trials.
Background and Aims Driver‐targeted ablation is a potential adjunct to pulmonary vein isolation (PVI) in persistent atrial fibrillation (PsAF), yet identifying drivers remains challenging. This study investigates whether voltage characteristics can facilitate driver identification. Methods In a multicenter retrospective exploratory cohort of 201 patients with PsAF undergoing PVI plus driver ablation, voltage characteristics within 241 driver regions were analyzed to derive an optimal voltage transition zone. A prospective validation cohort of 53 patients subsequently underwent ablation guided by this mapping approach. Results The optimal voltage threshold (0.16–0.61 mV) captured 78.8% of driver regions, which frequently exhibited a mosaic pattern at the interface of low‐, transition‐, and normal‐voltage areas. This approach outperformed conventional low‐voltage area–based identification (42.3%, p = 0.004). Mosaic pattern recognition using two voltage thresholds achieved 94.2% sensitivity and 77.1% specificity. Among cases without acute AF termination, the mosaic pattern was still observed in 87.5% of driver regions. In the validation cohort, acute AF termination (69.8%) and 12‐month freedom from atrial arrhythmias were comparable to the exploratory cohort, though freedom from AF was lower ( p = 0.035) but AF proportion among recurrences was reduced ( p = 0.009). Procedure time and number of drivers ablated were also decreased ( p = 0.001 and 0.003, respectively). Conclusion This work proposes a hypothesis that AF driver regions in PsAF frequently exhibit a mosaic pattern under optimized voltage thresholds, which may provide a feasible adjunct to electrogram‐guided mapping; whether this approach improves clinical outcomes remains to be determined.
No takes yet. Share an insight, caveat, or question.
Pang et al. (2026) conducted a cohort in Persistent Atrial Fibrillation (n=254). Mosaic pattern recognition using optimized voltage thresholds vs. Conventional low-voltage area-based identification was evaluated on Capture of driver regions (p=0.004). Mosaic pattern recognition using optimized voltage thresholds captured 78.8% of driver regions in persistent atrial fibrillation, outperforming conventional low-voltage area-based mapping.
Synapse has enriched 10 related papers. Consider them for comparative context: