Key result
In octogenarians with systolic heart failure, CRT-P was associated with similar 5-year all-cause mortality compared to CRT-D.
Why the study?
Does CRT-P confer similar morbidity and mortality benefits as CRT-D in octogenarian patients with systolic heart failure?
Cohort (n=246)
Yes
Does CRT-P confer similar morbidity and mortality benefits as CRT-D in octogenarian patients with systolic heart failure?
In octogenarians with systolic heart failure, CRT-P is associated with similar morbidity and mortality outcomes compared to CRT-D, suggesting the added defibrillator may not provide significant survival benefit in this age group.
Answers are grounded in this paper and cite their sources.
CRT-P may be considered in octogenarians to avoid ICD risks; this cohort study leaves open the need for RCTs to confirm equivalence.
AIMS: Cardiac resynchronization therapy (CRT) with a defibrillator (CRT-D) has downsides of high cost and inappropriate shocks compared to CRT without a defibrillator (CRT-P). Recent data suggest that the survival benefit of implantable cardioverter defibrillator (ICD) therapy is attenuated in the older age group. We hypothesized that, among octogenarians eligible for cardiac resynchronization therapy, CRT-P confers similar morbidity and mortality benefits as CRT-D. METHODS AND RESULTS: We compared morbidity and mortality outcomes between consecutive octogenarian patients eligible for CRT therapy who underwent CRT-P implantation at Barzilai MC (n = 142) vs. those implanted with CRT-D for primary prevention indication who were prospectively enrolled in the Israeli ICD Registry (n = 104). Among the 246 study patients, mean age was 84 ± 3 years, 74% were males, and 66% had ischaemic cardiomyopathy. Kaplan-Meier survival analysis showed that at 5 years of follow-up the rate of all-cause mortality was 43% in CRT-P vs. 57% in the CRT-D group [log-rank P = 0.13; adjusted hazard ratio (HR) = 0.79, 95% CI 0.46-1.35, P = 0.37]. Kaplan-Meier analysis also showed no significant difference in the rates of the combined endpoint of heart failure or death (46 vs. 60%, respectively, log-rank P = 0.36; adjusted HR was 0.85, 95% CI 0.51-1.44, P = 0.55). A Cox proportional hazard with competing risk model showed that re-hospitalizations for cardiac cause were not different for the two groups (adjusted HR 1.35, 95% CI 0.7-2.6, P = 0.37). CONCLUSION: Our data suggest that, in octogenarians with systolic heart failure, CRT-P therapy is associated with similar morbidity and mortality outcomes as CRT-D therapy.
No takes yet. Share an insight, caveat, or question.
Laish‐Farkash et al. (2016) conducted a cohort in Systolic heart failure eligible for cardiac resynchronization therapy (n=246). CRT-P vs. CRT-D was evaluated on All-cause mortality (adjusted HR 0.79, 95% CI 0.46-1.35, p=0.37). In octogenarians with systolic heart failure, CRT-P was associated with similar 5-year all-cause mortality compared to CRT-D.
Synapse has enriched 10 related papers. Consider them for comparative context: