Key result
Thrombin time significantly correlated with ECA-based argatroban (r=0.820) and lepirudin (r=0.830) levels (P<0.01), whereas aPTT showed poor correlation and high variability.
Why the study?
Does aPTT accurately reflect direct thrombin inhibitor levels compared to ECA in patients with HIT?
Observational (n=117)
Does aPTT accurately reflect direct thrombin inhibitor levels compared to ECA in patients with HIT?
Effect estimate: r = 0.820 for TT and argatroban; r = 0.830 for TT and lepirudin
p-value: p=<.01
Monitoring of direct thrombin inhibitors (DTIs) in patients with heparin-induced thrombocytopenia (HIT) is primarily performed using the activated partial thromboplastin time (aPTT). This assay is poorly standardized, reagent dependent, and not DTI specific. We compared aPTT, thrombin time (TT), and prothrombin time (PT) to drug levels obtained by the ecarin chromogenic assay (ECA). We analyzed 495 samples of patients with confirmed or suspected HIT on treatment with either argatroban (n = 37) or lepirudin (n = 80). Mean DTI levels ± standard deviation (SD) were 0.41 ± 0.36 µg/mL for argatroban and 0.20 ± 0.21 µg/mL for lepirudin. Results of aPTT were highly variable: 67 ± 22 seconds for argatroban and 55 ± 20 seconds for lepirudin. Significant correlations ( P < .01) were found between ECA-based DTI level and TT (argatroban, r = .820 and lepirudin, r = .830), PT (argatroban, r = -.544), and aPTT (lepirudin, r = .572). However, there was no correlation of aPTT with argatroban or PT with lepirudin concentration. Multiple regression analyses revealed that the TT predicted 54% of argatroban and 42% of lepirudin levels, but no significant impact was seen for PT or aPTT. The aPTT-guided monitoring of DTI therapy leads to a high percentage of patients with inaccurate plasma levels, hence resulting to either undertreatment or overtreatment. Knowledge of baseline values prior to DTI therapy and inclusion of clinical settings are essential for dosing DTIs when using aPTT. However, due to several limitations of aPTT, monitoring according to exact plasma concentrations as obtained by specific tests such as ECA may be more appropriate.
No takes yet. Share an insight, caveat, or question.
Seidel et al. (2017) conducted an observational in Heparin-induced thrombocytopenia (HIT) (n=117). aPTT, TT, and PT monitoring vs. Ecarin chromogenic assay (ECA) drug levels was evaluated on Correlation between ECA-based DTI level and TT, PT, and aPTT (r = 0.820 for TT and argatroban; r = 0.830 for TT and lepirudin, p=<.01). Thrombin time significantly correlated with ECA-based argatroban (r=0.820) and lepirudin (r=0.830) levels (P<0.01), whereas aPTT showed poor correlation and high variability.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: