Key result
The combination of baseline systolic dyssynchrony and a posterolateral left ventricular lead position predicted lower all-cause mortality after CRT.
Why the study?
Does combining a posterolateral left ventricular lead position with baseline systolic dyssynchrony predict better long-term survival in patients receiving cardiac resynchronization therapy?
Cohort (n=134)
Does combining a posterolateral left ventricular lead position with baseline systolic dyssynchrony predict better long-term survival in patients receiving cardiac resynchronization therapy?
Answers are grounded in this paper and cite their sources.
The placement of the LV lead at a posterolateral position provides additional prognostic value to baseline dyssynchrony in predicting lower long-term all-cause and cardiovascular mortality after CRT.
The efficacy of CRT (cardiac resynchronization therapy) can be affected by a number of factors; however, the prognostic significance of the LV (left ventricular) lead position has not been explored. The aim of the present study was to examine whether a PL (posterolateral) lead position has an additional value to systolic dyssynchrony in predicting a better survival after CRT. Patients (n=134) who received CRT were followed-up for 39+/-24 months. The LV lead position was determined by cine fluoroscopy, and baseline dyssynchrony was assessed by TDI (tissue Doppler imaging). The relationship between the LV lead position/dyssynchrony and mortality was compared using Kaplan-Meier curves, followed by Cox regression analysis. The all-cause and cardiovascular mortalities were 38 and 31% respectively. The presence of dyssynchrony and a PL lead position predicted a lower all-cause mortality (29 compared with 47%; log-rank chi2=5.38, P=0.02) and cardiovascular mortality (21 compared with 41%; log-rank chi2=6.75, P=0.009) than when absent. The all-cause mortality was as high as 62% when patients had neither dyssynchrony nor a PL lead position, but was reduced to 29% when both criteria were present, and was between 45 and 46% when only one criterion was present (chi2=6.79, P=0.01). The corresponding values for cardiovascular mortality were 62% when patients had neither dyssynchrony nor a PL lead position, 36-38% when patients had either dyssynchrony or a PL lead position, and 21% when patients had both criteria present (chi2=9.54, P=0.004). Combining dyssynchrony and a PL lead position independently predicted a lower all-cause morality {HR (hazard ratio), 0.496 [95% CI (confidence interval), 0.278-0.888]; P=0.018} and cardiovascular mortality [HR, 0.442 (95% CI, 0.232-0.844); P=0.013]. In conclusion, the placement of the LV lead at a PL position provides additional value to baseline dyssynchrony in predicting a lower all-cause and cardiovascular mortality during long-term follow-up after CRT.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2009) conducted a cohort in Cardiac resynchronization therapy recipients (n=134). Combined baseline systolic dyssynchrony and posterolateral left ventricular lead position vs. Absence of dyssynchrony and/or posterolateral lead position was evaluated on All-cause mortality (HR 0.496, 95% CI 0.278-0.888, p=0.018). The combination of baseline systolic dyssynchrony and a posterolateral left ventricular lead position predicted lower all-cause mortality after CRT.
Synapse has enriched 10 related papers. Consider them for comparative context: