Why the study?
The feasibility and clinical utility of cardiopulmonary exercise testing in patients with advanced heart failure requiring intravenous inotropic support remained unclear.
Does cardiopulmonary exercise testing (CPET) provide prognostic value in hospitalized patients with advanced heart failure requiring intravenous inotropes?
Observational (n=50)
Does cardiopulmonary exercise testing (CPET) provide prognostic value in hospitalized patients with advanced heart failure requiring intravenous inotropes?
Cardiopulmonary exercise testing is safe and feasible in highly selected hospitalized patients with advanced heart failure on intravenous inotropes, and the VE/VCO2 slope provides significant prognostic value for cardiovascular events.
VE/VCO2 slope may aid risk stratification in advanced HF on inotropes; hypothesis-generating and requires prospective validation.
Background: Cardiopulmonary exercise testing (CPET) is widely used for prognostic assessment and risk stratification in patients with heart failure (HF). However, its feasibility and clinical utility in patients with advanced HF requiring intravenous inotropic support remain unclear. Methods: This observational study included hospitalized patients with HF who received intravenous inotropic therapy and underwent CPET during index hospitalization. The primary outcome was a composite of HF rehospitalization or cardiovascular death. Results: A total of 528 patients hospitalized for HF required intravenous inotropic therapy; 50 patients were included. CPET was safely completed in all patients without exercise-related adverse events. The median peak VO2 was 12.5 mL/kg/min, and the median VE/VCO2 slope was 38.3. During a median follow-up of 762 days, 12 primary events occurred. In univariable analysis, the VE/VCO2 slope, O2 pulse, and maximal workload were significantly associated with the primary outcome, whereas peak VO2 was not. A VE/VCO2 slope > 38.2 was associated with a significantly higher 3-year event rate compared with a slope ≤ 38.2 (40% vs. 8%, p = 0.021). Conclusions: CPET is feasible and safe in highly selected patients with advanced HF requiring inotropic support, and the VE/VCO2 slope was associated with clinical outcomes in exploratory univariable analyses.
No takes yet. Share an insight, caveat, or question.
Nakagaito et al. (2026) conducted an observational in advanced heart failure (n=50). VE/VCO2 slope > 38.2 vs. VE/VCO2 slope ≤ 38.2 was evaluated on composite of HF rehospitalization or cardiovascular death (p=0.021).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: