Key result
Noninvasive measurements of total electromechanical systole and left ventricular ejection time during exercise demonstrated high reliability in healthy men.
Why the study?
Are noninvasive methods for measuring cardiac function reliable and reproducible during exercise in healthy men?
Observational (n=20)
Are noninvasive methods for measuring cardiac function reliable and reproducible during exercise in healthy men?
Noninvasive methods for measuring cardiac function, including systolic time intervals and indirect cardiac output, are reliable and reproducible during moderate to heavy exercise in healthy men.
Answers are grounded in this paper and cite their sources.
Supports noninvasive systolic time intervals during exercise in research; leaves open validation and clinical adoption.
Externally recorded systolic time intervals (STI's), indirect (CO2 re-breathing) cardiac output, and auscultatory blood pressures were measured during upright bicycle ergometer work in 20 healthy men, aged 24-56 yr. The subjects were studied on 2 separate days at steady-state work loads chosen to represent light (mean heart rate (HR) = 96 beats.min-1), moderate (HR = 118 beats.min-1) and heavy (HR = 147 beats.min-1) exercise. In addition to determinations of cardiac output, systolic time intervals, and blood pressure, the individual's mean systolic ejection rate (stroke volume/left ventricular ejection time) was calculated as a measure of left ventricular function. In general, heart-rate-corrected STI's were found to be reliable and reproducible. Reliability coefficients for total electromechanical systole and left ventricular ejection time ranged from 0.93 to 0.96 while those for the preejection period and its subcomponents were between 0.63 and 0.88. The reliability of cardiac output, stroke volume, mean systolic ejection rate, and systolic blood pressure was also considered to be acceptable but tended to be higher during moderate and heavy work (r = 0.85-0.95) compared to light exercise (r = 0.60-0.83).
No takes yet. Share an insight, caveat, or question.
Wolfe et al. (1978) conducted an observational in Healthy (n=20). Noninvasive methods for measuring cardiac function was evaluated on Reliability coefficients for total electromechanical systole and left ventricular ejection time (r = 0.93-0.96). Noninvasive measurements of total electromechanical systole and left ventricular ejection time during exercise demonstrated high reliability in healthy men.
Synapse has enriched 10 related papers. Consider them for comparative context: