Key result
Submaximum cycle ergometry yielded reliable steady-rate ventilation, oxygen uptake, and heart rate responses, but lower reliability for blood pressure.
Why the study?
What is the reliability and within-subject variability of physiological parameters during submaximum cycle ergometry?
What is the reliability and within-subject variability of physiological parameters during submaximum cycle ergometry?
During submaximum cycle ergometry, steady-rate ventilation, oxygen uptake, and heart rate are reliable measures, whereas blood pressure shows low reliability.
Answers are grounded in this paper and cite their sources.
Submaximal cycle ergometry yields reliable cardiorespiratory but not blood pressure responses; leaves open protocol standardization for clinical testing.
To assess the reliability and within subject variability of steady-rate ventilation (VE), oxygen uptake (VO2), heart rate, systolic and diastolic blood pressure, 4 subjects exercised for 10 minutes at 3 work rates on a bicycle ergometer: 50 W, 125 W and 55% of maximum work rate (55% max). Each testing session included two work rates and only 2 testing sessions were scheduled per week. The order of the work rates was counterbalanced. In 8 to 10 weeks, 3 of the subjects completed 20 trials at 50 W while the fourth subject completed 11 trials, and all the subjects completed 10 trials at 125 W and 55% max. The within subject variability (S2w) was expressed as a percent of the mean steady-rate response. VO2 ranged from 21.2% to 27.5% of VO2max at 50 W, from 37.7% to 49.7% at 125 W and from 42.9% to 63.7% at 55% max. The S2w averaged 6.8% for VE, 4.3% for VO2, 3.2% for heart rate, 7.3% for systolic blood pressure and 10.5% for diastolic blood pressure. Reliability coefficients were calculated for the steady-rate scores by dividing the between subject variation by the total variation. The reliability was similar for VE, VO2 and heart rate and ranged from r = 0.69 to r = 0.97. Systolic and diastolic blood pressure reliabilities were lower and ranged from r = 0.27 and r = 0.80. In summary, the steady-rate ventilation, oxygen uptake and heart rate responses were reliable and consistent. The reliability of blood pressure was low. It is possible that this low reliability may result from variability in stroke volume or total peripheral resistance.
No takes yet. Share an insight, caveat, or question.
Becque et al. (1993) studied this question. Submaximum cycle ergometry was evaluated on Reliability and within subject variability of steady-rate ventilation (VE), oxygen uptake (VO2), heart rate, and blood pressure. Submaximum cycle ergometry yielded reliable steady-rate ventilation, oxygen uptake, and heart rate responses, but lower reliability for blood pressure.