Key result
Constant work rate cycle exercise parameters show high test-retest repeatability in COPD patients.
Why the study?
The distribution profiles and repeatability of key exercise performance parameters during cycle ergometry in multicentre COPD trials were not well characterized.
Are ventilatory and perceptual parameters reliably measured during constant work rate cycle exercise in multicentre trials of COPD?
Observational (n=463)
Yes
Are ventilatory and perceptual parameters reliably measured during constant work rate cycle exercise in multicentre trials of COPD?
Answers are grounded in this paper and cite their sources.
Key perceptual and ventilatory parameters can be reliably measured during constant work rate cycle exercise in multicentre clinical trials for COPD.
We studied the distribution profiles and repeatability of key exercise performance parameters in the first large multicentre trials to include these measurements in chronic obstructive pulmonary disease (COPD). After a screening visit, 463 subjects with COPD (mean+/-SD forced expiratory volume in 1 s 43+/-13% predicted) completed two run-in visits before treatment randomisation. At the run-in visits, measurements were conducted at rest, at a standardised time near end-exercise (isotime) and at peak exercise during constant work rate (CWR) cycle tests at 75% of each individual's maximum work capacity. The intraclass correlation coefficient was used to evaluate the test-retest repeatability of measurements of endurance time (ET), inspiratory capacity (IC), ventilation and dyspnoea intensity (Borg scale) during exercise. IC, ventilation and dyspnoea ratings were normally distributed; ET showed rightward skew (median or = 0.87). Ventilation was repeatable over the same time-points (R > or = 0.92), as was dyspnoea intensity at isotime (R = 0.79) and at peak exercise (R = 0.81). In conclusion, key perceptual and ventilatory parameters can be reliably measured during CWR cycle exercise in multicentre clinical trials in moderate to very severe COPD.
No takes yet. Share an insight, caveat, or question.
O’Donnell et al. (2009) conducted an observational in chronic obstructive pulmonary disease (COPD) (n=463). Constant work rate (CWR) cycle tests at 75% of maximum work capacity was evaluated on Test-retest repeatability of measurements of endurance time (ET), inspiratory capacity (IC), ventilation and dyspnoea intensity during exercise. Constant work rate cycle exercise parameters, including inspiratory capacity and ventilation, showed high test-retest repeatability in multicentre trials of COPD patients.
Synapse has enriched 10 related papers. Consider them for comparative context: