Key result
Pulmonary transit time assessed by cardiovascular magnetic resonance yielded an AUC of 0.73 (P<0.001) for excluding heart failure and 0.70 (P<0.001) for including heart failure.
Why the study?
Pulmonary transit time may help in the diagnostic assessment and characterization of patients with unclear dyspnoea or heart failure, prompting evaluation of its quantification in routine cardiovascular magnetic resonance perfusion sequences.
Does pulmonary transit time (PTT) measured by cardiovascular magnetic resonance perfusion scans accurately identify patients with heart failure and elevated NT-proBNP?
Observational (n=352)
Does pulmonary transit time (PTT) measured by cardiovascular magnetic resonance perfusion scans accurately identify patients with heart failure and elevated NT-proBNP?
Effect estimate: AUC 0.73
p-value: p=<0.001
Pulmonary transit time derived from routine CMR perfusion scans is a robust, automatically obtainable non-invasive biomarker that correlates with reduced ejection fraction and NT-proBNP levels, aiding in heart failure evaluation.
PTT quantification from routine CMR perfusion may aid dyspnoea or HF assessment; leaves open its diagnostic utility pending validation.
AIMS: Pulmonary transit time (PTT) is the time blood takes to pass from the right ventricle to the left ventricle via pulmonary circulation. We aimed to quantify PTT in routine cardiovascular magnetic resonance imaging perfusion sequences. PTT may help in the diagnostic assessment and characterization of patients with unclear dyspnoea or heart failure (HF). METHODS AND RESULTS: We evaluated routine stress perfusion cardiovascular magnetic resonance scans in 352 patients, including an assessment of PTT. Eighty-six of these patients also had simultaneous quantification of N-terminal pro-brain natriuretic peptide (NTproBNP). NT-proBNP is an established blood biomarker for quantifying ventricular filling pressure in patients with presumed HF. Manually assessed PTT demonstrated low inter-rater variability with a correlation between raters >0.98. PTT was obtained automatically and correctly in 266 patients using artificial intelligence. The median PTT of 182 patients with both left and right ventricular ejection fraction >50% amounted to 6.8 s (Pulmonary transit time: 5.9-7.9 s). PTT was significantly higher in patients with reduced left ventricular ejection fraction (<40%; P < 0.001) and right ventricular ejection fraction (<40%; P < 0.0001). The area under the receiver operating characteristics curve (AUC) of PTT for exclusion of HF (NT-proBNP <125 ng/L) was 0.73 (P < 0.001) with a specificity of 77% and sensitivity of 70%. The AUC of PTT for the inclusion of HF (NT-proBNP >600 ng/L) was 0.70 (P < 0.001) with a specificity of 78% and sensitivity of 61%. CONCLUSION: PTT as an easily, even automatically obtainable and robust non-invasive biomarker of haemodynamics might help in the evaluation of patients with dyspnoea and HF.
No takes yet. Share an insight, caveat, or question.
Segeroth et al. (2023) conducted an observational in unclear dyspnoea or heart failure (n=352). Pulmonary transit time (PTT) assessment was evaluated on Diagnostic performance of PTT for exclusion of heart failure (NT-proBNP <125 ng/L) (AUC 0.73, p=<0.001). Pulmonary transit time assessed by cardiovascular magnetic resonance yielded an AUC of 0.73 (P<0.001) for excluding heart failure and 0.70 (P<0.001) for including heart failure.