Key result
Repeated balloon aortic valvuloplasty significantly decreased peak aortic valve gradient from a median of 73.0 mm Hg to 45.0 mm Hg, achieving acute hemodynamic results comparable to the index procedure.
Why the study?
Long-term outcomes of balloon aortic valvuloplasty in severe symptomatic aortic stenosis are poor, necessitating repeated procedures in select cases, but the safety and efficacy of repeated procedures needed investigation.
Does repeated balloon aortic valvuloplasty improve hemodynamics and what is its safety profile in patients with symptomatic severe aortic stenosis?
Cohort (n=35)
Yes
Does repeated balloon aortic valvuloplasty improve hemodynamics and what is its safety profile in patients with symptomatic severe aortic stenosis?
Absolute Event Rate: 45% vs 73%
p-value: p=<0.001
reBAV may be feasible in selected severe AS patients; leaves open need for prospective trials before clinical adoption.
BACKGROUND: Long-term outcomes of balloon aortic valvuloplasty (BAV) in patients with severe symptomatic aortic stenosis (AS) are poor, and this procedure needs to be repeated in selected cases. AIMS: We aimed to investigate the safety and efficacy of repeated BAV (reBAV). METHODS: We included consecutive patients who underwent reBAV in three Polish centers between 2010 and 2019. Baseline clinical, echocardiographic, procedural, and outcome data were analyzed. RESULTS: Thirty-five patients (median age 81.5 years, 57.1% women) who underwent reBAV were enrolled. In 42.9% of the patients, index BAV was considered a palliative treatment, and in 54.3% a bridge to definitive treatment. Index BAV decreased peak aortic valve gradient (pAVG) from a median of 78.0 mm Hg to 46.0 mm Hg (P <0.001). After a mean of 255.8 days, reBAV was performed. In most cases (71.4%), the reason for reBAV was the worsening of heart failure symptoms and in 54.3% of patients, reBAV was still considered a palliative option. A decrease in pAVG max from a median of 73.0 mm Hg to 45.0 mm Hg (P <0.001), comparable to index BAV, was observed. The frequency of complications were numerically higher for repeated procedures. During the median (IQR) follow-up of 403.0 (152.0-787.0) days from the index procedure, 80.0% of the patients died. CONCLUSIONS: Acute hemodynamic results of reBAV are comparable to those achieved during index BAV. However, reBAV may carry an increased risk of complications. Moreover, mortality is high due to unfavorable risk profiles or delays in receiving definitive therapy.
No takes yet. Share an insight, caveat, or question.
Sorysz et al. (2023) conducted a cohort in Symptomatic severe aortic stenosis (n=35). Repeated balloon aortic valvuloplasty (reBAV) vs. Pre-procedure baseline was evaluated on Peak aortic valve gradient (pAVG) (p=<0.001). Repeated balloon aortic valvuloplasty significantly decreased peak aortic valve gradient from a median of 73.0 mm Hg to 45.0 mm Hg, achieving acute hemodynamic results comparable to the index procedure.