Pacemaker system overview leaves open optimal lead selection and programming strategies; prospective trials needed before practice changes.
A pacemaker is a device that provides electrical stimuli to maintain or restore a normal heartbeat. Pacing systems are made of 2 implantable cardiac components (the pacemaker pulse generator and the intracardiac leads), and can be interrogated by using a wireless, telemetered, external programming device.1 Pacemakers can be dual- or single-chamber. Single-chamber pacemakers have a single lead, which is placed either into the right atrium or, more often, into the right ventricle. Dual-chamber pacemakers have 2 leads, with one in the right atrium and the other in the right ventricle.2Patients with pacemakers generally face problems that can be grouped into the following categories3:A failure of output is suspected if the heart rate is below the programmed lower rate of the pacemaker and no pacer electrical output is noted on the electrocardiogram (ECG)—that is, pacing spikes are absent. Causes of output failure are generally lead failure (lead fracture, lead displacement), generator failure, battery failure, crosstalk inhibition, or oversensing (Fig. 1).4Capture failure occurs when the generated pacing stimulus does not initiate myocardial depolarization. On the surface ECG, pacing spikes are present, but they are not followed by a QRS complex in the event of ventricular noncapture or by the lack of P waves in the event of atrial noncapture (Fig. 2). The main causes of this failure are lead dislodgment, low output, lead maturation, and lead or pacer failure (fibrosis, fracture, low pacing voltage, or elevated myocardial pacing thresholds).5The pacing threshold is the minimum required energy that consistently triggers a depolarization of the paced chamber. Multiple factors—including antiarrhythmic drug use, physical activity level, posture, time of day, and comorbidity—could all affect the pacing threshold.6Undersensing occurs when the pacemaker fails to detect spontaneous myocardial depolarization, which results in asynchronous pacing. Atrial or ventricular pacing spikes arise regardless of P waves or QRS complex. This typically results in the appearance of too many pacing spikes, as seen on ECG (Fig. 3). The main causes of undersensing are pacemaker programming problems (improper sensing threshold), insufficient myocardial voltage signal, lead or pacer failure (fibrosis, fracture, etc.), or an electrolyte abnormality.7Oversensing occurs when the pacemaker senses electrical signals that it should not normally encounter, which results in inappropriate inhibition of the pacing stimulus. In addition to the native cardiac depolarization signals (P or R waves), any electrical signal with sufficient amplitude and frequent occurrence can be sensed and can inhibit the pacemaker when pacing is needed. Oversensing can be caused by physiologic signals like T waves or by myopotential (and nonphysiologic) signals like electromagnetic interference or a lead failure (an insulation break or a lead fracture) (Fig. 4).7“Ventricular fusion” is the electrical summation of a heart's intrinsic beat and a depolarization from a pacing stimulus. The hallmark of this phenomenon is that its morphology lies between a fully paced beat and a complete intrinsic beat. On the other hand, when the pacemaker spikes fall directly on top of an intrinsic beat, without contributing to the actual depolarization, this event is called “pseudofusion” beat.7 Fusion and pseudofusion beats are both consistent with normal pacemaker behavior (Fig. 5).Pseudomalfunctions are unusual and unexpected ECG findings that appear to be pacemaker malfunctions but actually are normal pacemaker behavior. Pseudomalfunctions are classified under 3 categories: 1) rate-related, 2) atrioventricular (AV) interval/refractory period-related, and 3) model-related.Most common are the rate-related pseudomalfunctions. Rate changes in the presence of normal pacemaker function can occur because of magnet operation, timing variations (A-A vs V-V), upper-rate behavior (Wenckebach or 2:1 block), pacemaker-mediated tachycardia (PMT), or rate response.7The following paragraphs cover some of the typical clinical situations presenting as pseudomalfunctions.Ventricular Safety Pacing. Ventricular safety pacing (SP) prevents ventricular asystole due to crosstalk. Pacemaker crosstalk in a dual-chamber pacemaker refers to the detection of a paced signal in one chamber by the lead in another chamber, and to the misrepresentation of the paced signal as a cardiac depolarization signal. This, in turn, results in inappropriate inhibition of pacing in the 2nd chamber.8Ventricular safety pacing delivers a ventricular pacing stimulus after detecting a ventricular “sense event” shortly after an atrial paced event (SP algorithms differ among pacemaker manufacturers).9 Ventricular safety pacing typically results in the appearance of 2 very closely spaced atrial and ventricular paced events on ECG (Fig. 6).Pacemaker-Mediated Tachycardia. Pacemaker-mediated tachycardia is an endless-loop tachycardia, sustained, in part, by the presence of the pacemaker. Pacemaker-mediated tachycardia requires the presence of retrograde ventriculoatrial conduction and a triggering event like premature ventricular contraction or loss of AV synchrony. Pacemaker-mediated tachycardia is similar to a re-entrant tachycardia, except that the pacemaker forms part of the re-entrant circuit; the tachycardia could therefore be avoided by programming a sufficiently long postventricular atrial refractory period (PVARP).10 Placing a magnet on the device during the PMT will change the pacemaker's mode to dual-chamber pacing mode (in DOO, intrinsic P waves and R waves are ignored), which results in the termination of tachycardia by suspending the pacemaker's sensing function (Fig. 7).4,10Upper-Rate Behavior. Upper-rate behavior refers to the pacing characteristics seen in dual-chambered pacemakers programmed to an atrial tracking mode as the atrial rate increases and approaches a certain upper threshold. In dual-chambered devices, it is necessary to limit the rate at which the ventricle can pace in the presence of high atrial rates. This limit is called the maximum tracking rate (MTR) and is a programmable value. The upper-rate behavior depends upon MTR and total atrial refractory period (TARP). The TARP is equal to AV delay + PVARP. When the atrial rate exceeds MTR, it results in pacemaker Wenckebach. If the atrial rate keeps increasing and exceeds the TARP, it will result in pacemaker 2:1 AV block.3
No takes yet. Share an insight, caveat, or question.
Safavi‐Naeini et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: