A novel noniterative ultrasound Doppler technique can estimate arterial wall viscoelastic properties with reasonable accuracy in simulations and phantom models, potentially aiding in early atherosclerosis diagnosis.
Answers are grounded in this paper and cite their sources.
High errors limit near-term clinical use; leaves open whether Doppler viscoelastic imaging can aid atherosclerosis detection.
Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.
No takes yet. Share an insight, caveat, or question.
Balocco et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: