Answers are grounded in this paper and cite their sources.
A method is described for the simultaneous determination of cholesterol, phytosterols and tocopherols in dairy and non-dairy high-performance liquid chromatography. A facile saponification and extraction scheme is completed rapidly within a single reaction tube. Clean-up is not required, with analysis completed by one of two alternative reversed-phase approaches. Sterols are monitored by short-wave ultraviolet spectrophotometry, and tocopherols by means of a series fluorescence detector. Cholesterol is resolved from the principal plant phytosterols, while the tocopherol congeners are well separated, thereby offering complementary information regarding source-lipid composition in foods under regulatory quality-control conditions. Squalene, an essential metabolic sterol precursor, can also be determined concurrently at the same viewing wavelength.
No takes yet. Share an insight, caveat, or question.
Harvey E. Indyk (1990) studied this question.