Why the study?
Does serum digoxin measurement improve the identification of digitalis toxicity compared to empiric methods in patients treated with digitalis?
Does serum digoxin measurement improve the identification of digitalis toxicity compared to empiric methods in patients treated with digitalis?
Answers are grounded in this paper and cite their sources.
Serum digoxin measurement is superior to empiric calculations based on renal function and body weight for identifying digitalis toxicity.
A prospective study of consecutive patients admitted to a medical service was undertaken to evaluate the prevalence of cardiac digitalis toxicity and the relative diagnostic values of serum digoxin versus an empiric method, based on calculations of digoxin dose in relation to kidney function and body weight. Of 711 patients admitted, 109 were treated with digitalis on admission. Sixteen of the patients developed cardiac arrhythmias consistent with digitalis intoxication. Five of these, none with serum digoxin above 1.6 ng/ml, were not toxic. The remaining eleven patients, all with serum digoxin levels above 1.6 ng/ml, were either definitely or possibly toxic. A similar borderline between intoxicated and nonintoxicated patients could not be established on the basis of calculations based on body weight and renal function. In all cases in which suspicion of digitalis intoxication was raised, serum digoxin measurements could discriminate between the toxic and the nontoxic patients.
No takes yet. Share an insight, caveat, or question.
Waldorff et al. (1978) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: