Why the study?
Does a novel brachial occlusion-cuff technique accurately measure cardiac output compared to the open-circuit acetylene washin method in healthy individuals?
Does a novel brachial occlusion-cuff technique accurately measure cardiac output compared to the open-circuit acetylene washin method in healthy individuals?
The novel brachial occlusion-cuff technique provides similar cardiac output measurements to the established open-circuit acetylene method at rest and during light to moderate exercise.
Answers are grounded in this paper and cite their sources.
Novel single-cuff method may enable noninvasive CO assessment; leaves open accuracy and utility pending validation.
Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was −0.25 ± 1.02 l/min, Pearson’s correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson’s correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R 2 = 0.75 at rest and RPC = 2 l/min with R 2 = 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.
No takes yet. Share an insight, caveat, or question.
Sajgalik et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: