Why the study?
Multi-beat analysis is a novel pulse wave analysis method, but its cardiac output estimation required evaluation in patients undergoing off-pump coronary artery bypass surgery.
Does cardiac output estimation using multi-beat analysis of the radial arterial blood pressure waveform show agreement with intermittent pulmonary artery thermodilution in adult patients undergoing off-pump coronary artery bypass surgery?
Does cardiac output estimation using multi-beat analysis of the radial arterial blood pressure waveform show agreement with intermittent pulmonary artery thermodilution in adult patients undergoing off-pump coronary artery bypass surgery?
Multi-beat analysis of the radial arterial blood pressure waveform provides reasonable agreement and trending ability for cardiac output estimation compared to pulmonary artery thermodilution during off-pump coronary artery bypass surgery.
Answers are grounded in this paper and cite their sources.
Supports cautious use of multi-beat analysis for CO monitoring in OPCAB; leaves open interchangeability with thermodilution pending further validation.
Pulse wave analysis enables stroke volume to be estimated from an arterial blood pressure waveform. Multi-beat analysis is a novel pulse wave analysis method. We aimed to investigate cardiac output (CO) estimations using multi-beat analysis of the radial arterial blood pressure waveform in patients undergoing off-pump coronary artery bypass surgery (OPCAB) using intermittent pulmonary artery thermodilution (PATD) as the reference method. This was a prospective clinical method comparison study. In 58 patients, we measured CO using PATD (PATD-CO; reference method) and simultaneously recorded the radial arterial blood pressure waveform that we used for off-line estimation of CO based on multi-beat analysis (MBA-CO; test method) using the Argos CO monitor (Retia Medical; Valhalla, NY, USA). The final analysis was performed using 572 paired CO measurements. We performed Bland-Altman analysis accounting for multiple observations per patient. To describe the ability of the test method to track changes in CO over time we computed four-quadrant plots using a central exclusion zone of 15% and calculated the concordance rate. Mean PATD-CO was 4.13 ± 1.26 L/min and mean MBA-CO was 4.31 ± 1.25 L/min. The mean of the differences between PATD-CO and MBA-CO was - 0.20 L/min with a standard deviation of ± 1.14 L/min and 95% limits of agreement of - 2.48 to + 2.08 L/min. The concordance rate for CO changes between PATD-CO and MBA-CO was 89%. CO estimations using multi-beat analysis (Argos monitor) show reasonable agreement and trending ability compared with PATD-CO as the reference method in adult patients during OPCAB.
No takes yet. Share an insight, caveat, or question.
Saugel et al. (2019) studied this question.