Why the study?
Does appropriately timed atrial systole increase stroke volume in dogs with chronic heart block?
Does appropriately timed atrial systole increase stroke volume in dogs with chronic heart block?
Appropriately timed atrial systole contributes a small but significant 7-8% increase to stroke volume in a canine model of chronic heart block.
Contributes modestly to stroke volume in canine heart block; hypothesis-generating and should not yet inform human AV timing.
In dogs studied without thoracotomy, under morphine-pentobarbital anesthesia and with an average heart rate of 71 beats/minute, atrial systole contributes to ventricular function to a small but significant degree. Stroke volume increased by 7 to 8% when atrial systole was timed to occur 0.1 second prior to closure of the atrioventricular valves, and decreased a similar magnitude when the contribution of atrial systole to ventricular filling was rendered ineffective by the use of an A-V delay of zero so that atrial emptying into the ventricles was prevented by the closed A-V valves. Increases or decreases in right atrial pressure of several centimeters of water induced by infusion of 6% dextran and by hemorrhage, respectively, were not associated with demonstrably significant alterations in these effects.
No takes yet. Share an insight, caveat, or question.
Snyder et al. (1966) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: