Objective To investigate the echocardiography diagnosis and imaging features of prenatal closure of the fetal ductus arteriosus. Methods From January 2014 to June 2016, 7 cases of prenatal closure of the fetal ductus arterious were selected. The diagnosis were confirmed by echocardiography after delivery. The indexes including the right atrium diameter, right ventricular diameter, tricuspid valveregurgitation velocity, estimated right ventricular systolic pressure, pulmonary artery diameter, and pulmonary valves regurgitation velocity were mesured. In 24 hours and 3 months after birth respectively, the echocardiography indicators above were evaluated again. Results All of the 7 cases of prenatal closure of the fetal ductus arteriosus did not show ductus arteriosus and blood flow signal in echocardiogram. At the same time, it also showed the rightchambers enlargement. The average diameter of right atrium was 14.4 mm, right ventricle was 14.8 mm. Tricuspid valve regurgitation were mild to moderate or more serious. Average tricuspid valve regurgitation velocity was 367 cm/s and estimated right ventricular systolic blood pressure was 61 mmHg(1 mmHg=0.133 kPa). All fetal pulmonary arteries broadened in a different degree. Average diameter of pulmonary artery was 10.2 mm while pulmonary artery and aortic diameter ratio was >1.2. Pulmonary valve regurgitation were mild to moderate or more serious and regurgitation velocity averaged 247 cm/s. The results of echocardiography in 24 h after birth were reviewed. Ductus arteriosus and blood flow signal were not detected in all 7 cases. Right atrial diameter was reduced to 13.8 mm and right ventricular diameter to 11.8 mm. Average tricuspid valve regurgitation velocity was significantly reduced to 247 cm/s and estimated right ventricular systolic blood pressure was 19 mmHg. The average diameter of pulmonary artery in all patients was improved, and the average diameter was 9.1 mm. After 3 months, right atrial and right ventricular diameter and pulmonary arterial pressure were all recovered to normal range. In 5 cases, tricuspid valveregurgitation disappeared. The rest 2 cases had mild tricuspid valve regurgitation. Conclusions For comprehensive judgment of prenatal closure of the fetal ductus arteriosus patients' condition, it is important to detect early the three vessel trachea view and the ductus arteriosus view and combined with pulmonary arterial hypertension and right heart overload of ultrasonic performance.
No takes yet. Share an insight, caveat, or question.
Wei Wang (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: