Key result
iPhone carotid waveform analysis strongly correlates with cardiac MRI for measuring LVEF.
Why the study?
The accuracy of noninvasive left ventricular ejection fraction derived from carotid waveform intrinsic frequencies needed to be evaluated against cardiac MRI.
Does noninvasive carotid waveform analysis using an iPhone camera and intrinsic frequency algorithm accurately measure left ventricular ejection fraction compared to cardiac MRI in adults?
Cross-Sectional (n=72)
No
Does noninvasive carotid waveform analysis using an iPhone camera and intrinsic frequency algorithm accurately measure left ventricular ejection fraction compared to cardiac MRI in adults?
Noninvasive carotid waveform analysis using an iPhone camera and intrinsic frequency methodology provides rapid, bedside LVEF measurements with accuracy comparable to cardiac MRI without requiring calibration or training.
Answers are grounded in this paper and cite their sources.
Noninvasive intrinsic frequency LVEF estimation may enable portable assessment; leaves open clinical adoption pending larger validation studies.
Objective: The study is based on previously reported mathematical analysis of arterial waveform that extracts hidden oscillations in the waveform that we called intrinsic frequencies. The goal of this clinical study was to compare the accuracy of left ventricular ejection fraction derived from intrinsic frequencies noninvasively versus left ventricular ejection fraction obtained with cardiac MRI, the most accurate method for left ventricular ejection fraction measurement. Design: After informed consent, in one visit, subjects underwent cardiac MRI examination and noninvasive capture of a carotid waveform using an iPhone camera (The waveform is captured using a custom app that constructs the waveform from skin displacement images during the cardiac cycle.). The waveform was analyzed using intrinsic frequency algorithm. Setting: Outpatient MRI facility. Subjects: Adults able to undergo MRI were referred by local physicians or self-referred in response to local advertisement and included patients with heart failure with reduced ejection fraction diagnosed by a cardiologist. Interventions: Standard cardiac MRI sequences were used, with periodic breath holding for image stabilization. To minimize motion artifact, the iPhone camera was held in a cradle over the carotid artery during iPhone measurements. Measurements and Main Results: Regardless of neck morphology, carotid waveforms were captured in all subjects, within seconds to minutes. Seventy-two patients were studied, ranging in age from 20 to 92 years old. The main endpoint of analysis was left ventricular ejection fraction; overall, the correlation between ejection fraction–iPhone and ejection fraction–MRI was 0.74 (r = 0.74; p < 0.0001; ejection fraction–MRI = 0.93 × [ejection fraction–iPhone] + 1.9). Conclusions: Analysis of carotid waveforms using intrinsic frequency methods can be used to document left ventricular ejection fraction with accuracy comparable with that of MRI. The measurements require no training to perform or interpret, no calibration, and can be repeated at the bedside to generate almost continuous analysis of left ventricular ejection fraction without arterial cannulation.
No takes yet. Share an insight, caveat, or question.
Pahlevan et al. (2017) conducted a cross-sectional in Adults able to undergo MRI, including patients with heart failure with reduced ejection fraction (n=72). Noninvasive carotid waveform capture via iPhone camera analyzed with intrinsic frequency algorithm vs. Standard cardiac MRI was evaluated on Left ventricular ejection fraction (LVEF) (r = 0.74, p=<0.0001). Noninvasive iPhone carotid waveform analysis using intrinsic frequency strongly correlated with cardiac MRI for measuring LVEF.
Synapse has enriched 10 related papers. Consider them for comparative context: