Why the study?
Does contact force-guided ablation using Lesion Size Index improve procedural efficiency and safety compared to non-contact force-guided ablation in patients with symptomatic atrial flutter?
Does contact force-guided ablation using Lesion Size Index improve procedural efficiency and safety compared to non-contact force-guided ablation in patients with symptomatic atrial flutter?
Using a Lesion Size Index (LSI) >5 during contact force-guided ablation is an effective and safe parameter for achieving bidirectional block in the cavotricuspid isthmus for atrial flutter.
Answers are grounded in this paper and cite their sources.
May support LSI-guided CTI ablation; leaves open prospective validation versus standard CF parameters.
The application of optimum contact force (CF) can be used to improve ablation procedure success and safety. The lesion size index (LSI) is a novel dimensionless contact force parameter that allows for an accurate estimation of lesion volume in real time by integrating contact force (grams), duration (seconds) and power (watts). The aim was to correlate LSI values with current contact force parameters to achieve successful and safe bidirectional block of the cavotricuspid isthmus (CTI) using a maximum voltage-guided (MVG) ablation strategy. Fifteen consecutive patients (age 69 ± 7.9 years, nine males) with symptomatic atrial flutter (AFL) were evaluated and compared with 23 control (age 66.3 ± 10.4 years, 16 males) non-contact force-guided ablation cases. Irrigated-tip force-sensing ablation catheters (TactiCath Quartz™, St. Jude Medical, St. Paul, MN, USA) were used in the CF group to achieve the primary endpoint of complete bidirectional block of the isthmus. In the CF group, a total of 233 radiofrequency (RF) applications were examined. A mean LSI of 6.4 ±1.0 correlated with a force-time integral (FTI) of 581.2 ±230.9 g/s and an average CF of 13.9 ±4.9 g concurrently. Intraprocedural, fluoroscopy time and RF time demonstrated lower trends in the CF group, but no significance with respect to these trends was observed. The secondary endpoint of no reconnection within 20 min after the procedure was equally attained in both groups, and, likewise, the level of safety was comparable. An LSI value of >5 represents a new effective parameter in MVG ablation for the cavotricuspid region that demonstrates a safe profile. Guidance of CTI ablation using LSI and other contact force parameters of CF 13.9 ±4.9 g and FTI 581.2 ±230.9 g/s demonstrated highly effective and safe outcomes.
No takes yet. Share an insight, caveat, or question.
Boles et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: