Why the study?
Does contrast-enhanced US angiography accurately depict carotid artery stenosis compared to conventional angiography in patients with carotid artery disease?
Does contrast-enhanced US angiography accurately depict carotid artery stenosis compared to conventional angiography in patients with carotid artery disease?
Contrast-enhanced US angiography with FS069 accurately depicts severe carotid stenosis and correlates strongly with conventional angiography.
Answers are grounded in this paper and cite their sources.
May support noninvasive carotid stenosis assessment; leaves open prospective outcome trials before clinical adoption.
B-mode ultrasonographic (US) angiography enhanced with a microbubble-based US contrast agent (FS069) was evaluated in human subjects with carotid artery disease. Results at contrast material-enhanced US angiography and duplex US were compared with those at conventional angiography. Both US angiography and duplex US accurately depicted stenoses of 70% or more compared with those depicted at conventional angiography. The percentage diameter stenosis of the internal carotid artery measured at US angiography strongly correlated with that measured at conventional angiography (r = 0.988). The percentage area stenosis measured at US angiography strongly correlated with ex vivo measurements of the resected carotid plaque at magnetic resonance imaging (r = 0.979). US angiography depicted unsuspected wall irregularities, ulceration, and dissection.
No takes yet. Share an insight, caveat, or question.
Kono et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: