Why the study?
Does storage at -20 degrees C without protease inhibitors affect the stability of endogenous BNP and NT-proBNP in plasma samples?
Does storage at -20 degrees C without protease inhibitors affect the stability of endogenous BNP and NT-proBNP in plasma samples?
NT-proBNP is stable in frozen plasma at -20°C for at least four months, whereas BNP degrades rapidly and its measurement may not be valid under these conditions.
Answers are grounded in this paper and cite their sources.
BNP results from -20°C-stored plasma without inhibitors may be unreliable; leaves open optimal storage protocols for future BNP research.
The aim of the present study was to assess the long-term stability of endogenous B-type natriuretic peptide (BNP) and amino terminal proBNP (NT-proBNP) in plasma samples stored at -20 degrees C without addition of protease inhibitors (e.g., aprotinin). Stability of BNP and NT-proBNP was tested in 60 EDTA plasma samples with BNP values between 30 and 420 pg/ml. Initial BNP and NT-proBNP plasma concentrations were determined within four hours after blood collection using the AxSYM BNP and the Elecsys NT-proBNP assays. Subsequently, all samples were stored at -20 degrees C and were thawed for the second BNP and NT-proBNP determination on the two instruments after one day, 30 days, 60 days, 90 days and 120 days, respectively. Mean recovery (i.e., residual immunoreactivity) of BNP and NT-proBNP expressed in percent of the initial value for the given time interval of storage was calculated. Mean recovery of BNP was less than 70% after one day of storage at -20 degrees C and decreased to less than 50% after two to four months of storage (e.g., recovery of endogenous BNP after three months of storage at -20 degrees C ranging from 0% to 71%). In contrast, mean recovery of NT-proBNP was generally greater than 90%, irrespective of the duration of storage at -20 degrees C (e.g., recovery of endogenous NT-proBNP after three months of storage at -20 degrees C ranging from 91% to 112%). In conclusion, the determination of endogenous BNP with the AxSYM assay using frozen plasma samples may not be valid under the conditions tested. In contrast, NT-proBNP as measured by the Elecsys assay may be stored at -20 degrees C for at least four months without a relevant loss of the immunoreactive analyte.
No takes yet. Share an insight, caveat, or question.
Mueller et al. (2004) studied this question.