Key result
Linearized MSPa velocity does not differ between HCM patients and healthy controls.
Why the study?
The propagation velocity of myocardial stretch post-atrial contraction (MSPa) was proposed as a measure of left ventricular stiffness, but had not been investigated in hypertrophic cardiomyopathy.
Does the propagation velocity of myocardial stretch post-atrial contraction (MSPa) measured by high-frame-rate tissue Doppler imaging differ between patients with hypertrophic cardiomyopathy and healthy volunteers?
Case-Control (n=75)
No
Does the propagation velocity of myocardial stretch post-atrial contraction (MSPa) measured by high-frame-rate tissue Doppler imaging differ between patients with hypertrophic cardiomyopathy and healthy volunteers?
Answers are grounded in this paper and cite their sources.
Simple linear velocity measurements of myocardial stretch post-atrial contraction do not differentiate HCM from normal hearts because 42% of HCM patients exhibit non-linear mid-septal acceleration related to severe septal hypertrophy.
In cardiac high-frame-rate color tissue Doppler imaging (TDI), a wave-like pattern travels over the interventricular septum (IVS) after atrial contraction. The propagation velocity of this myocardial stretch post-atrial contraction (MSPa) was proposed as a measure of left ventricular stiffness. The aim of our study was to investigate the MSPa in patients with hypertrophic cardiomyopathy (HCM) compared with healthy volunteers. Forty-two healthy volunteers and 33 HCM patients underwent high-frame-rate (>500 Hz) TDI apical echocardiography. MSPa was visible in TDI, M-mode and speckle tracking. When assuming a wave propagating with constant velocity, MSPa in healthy volunteers (1.6 ± 0.3 m/s) did not differ from that in HCM patients (1.8 ± 0.8 m/s, p = 0.14). Yet, in 42% of patients with HCM, the MSPa had a non-constant velocity over the wall: in the basal IVS, the velocity was lower (1.4 ± 0.5 m/s), and in the mid-IVS, much higher (6.1 ± 3.4 m/s, p < 0.0001), and this effect was related to the septal thickness. The reason is hypothesized to be the reaching of maximal longitudinal myocardial distension in HCM patients.
No takes yet. Share an insight, caveat, or question.
Strachinaru et al. (2019) conducted a case-control in Hypertrophic cardiomyopathy (n=75). Hypertrophic cardiomyopathy (evaluated via high-frame-rate tissue Doppler imaging) vs. Healthy volunteers was evaluated on Linearized propagation velocity of myocardial stretch post-atrial contraction (MSPa) in m/s (p=0.14). Linearized MSPa velocity did not differ between HCM patients and healthy controls, though 42% of HCM patients showed non-constant mid-septal acceleration.