Key result
Patient-specific heart simulation successfully identified responders and non-responders to cardiac resynchronization therapy using the simulated relative change in maximum dP/dt.
Why the study?
Attempts to identify non-responders to cardiac resynchronization therapy using various biomarkers have not been successful to date.
Does patient-specific computer simulation of CRT using %ΔdP/dtmax identify clinical responders to CRT in heart failure patients?
Observational (n=8)
Single-blind
No
Does patient-specific computer simulation of CRT using %ΔdP/dtmax identify clinical responders to CRT in heart failure patients?
Patient-specific computer simulation of CRT using a multi-scale heart simulator can accurately predict clinical response by evaluating acute improvements in left ventricular pressure development.
Answers are grounded in this paper and cite their sources.
May refine CRT selection via simulation; hypothesis-generating and requires prospective validation before practice change.
To identify non-responders to cardiac resynchronization therapy (CRT), various biomarkers have been proposed, but these attempts have not been successful to date. We tested the clinical applicability of computer simulation of CRT for the identification of non-responders. We used the multi-scale heart simulator “UT-Heart,” which can reproduce the electrophysiology and mechanics of the heart based on a molecular model of the excitation–contraction mechanism. Patient-specific heart models were created for eight heart failure patients who were treated with CRT, based on the clinical data recorded before treatment. Using these heart models, bi-ventricular pacing simulations were performed at multiple pacing sites adopted in clinical practice. Improvement in pumping function measured by the relative change of maximum positive derivative of left ventricular pressure (%Δd P /d t max ) was compared with the clinical outcome. The operators of the simulation were blinded to the clinical outcome. In six patients, the relative reduction in end-systolic volume exceeded 15% in the follow-up echocardiogram at 3 months (responders) and the remaining two patients were judged as non-responders. The simulated %Δd P /d t max at the best lead position could identify responders and non-responders successfully. With further refinement of the model, patient-specific simulation could be a useful tool for identifying non-responders to CRT.
No takes yet. Share an insight, caveat, or question.
Isotani et al. (2020) conducted an observational in Heart failure (n=8). Patient-specific heart simulation (UT-Heart) vs. Clinical outcome (responders vs non-responders) was evaluated on Identification of CRT responders vs non-responders using simulated relative change in maximum dP/dt (%ΔdP/dtmax). Patient-specific heart simulation successfully identified responders and non-responders to cardiac resynchronization therapy using the simulated relative change in maximum dP/dt.
Synapse has enriched 10 related papers. Consider them for comparative context: