Key result
RF needle transseptal puncture achieves ~100% success with low fluoroscopy time using 3D mapping.
Why the study?
To evaluate the safety, usefulness, and radiation exposure of direct radiofrequency needle tip visualization on a 3D electroanatomical mapping system during transseptal puncture in an unselected patient cohort.
Is transseptal puncture using a radiofrequency needle with 3D electroanatomical mapping tip visualization safe and effective for reducing radiation exposure in patients undergoing left-sided catheter ablation?
Observational (n=41)
No
Is transseptal puncture using a radiofrequency needle with 3D electroanatomical mapping tip visualization safe and effective for reducing radiation exposure in patients undergoing left-sided catheter ablation?
Direct visualization of a radiofrequency transseptal needle on a 3D electroanatomical mapping system enables safe, 100% successful left atrial access with ultra-low or zero fluoroscopy exposure, even in patients with prior transseptal punctures or congenital heart disease with septal patches.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for ultra-low fluoroscopy transseptal access; prospective trials needed before clinical adoption.
Introduction . Transseptal puncture (TSP) is a routine access route in patients with left-sided ablation substrates and is performed safely on fluoroscopy (+/− echocardiographic guidance). We report on our experience using a radiofrequency (RF) needle in an unselected group of patients to demonstrate safety and usefulness of direct tip visualization on the 3D electroanatomical mapping (EAM) system with specific emphasis on total radiation exposure. Methods and Results . We retrospectively reviewed 42 consecutive left-sided ablation procedures with TSP performed using an RF needle guided by fluoroscopy and/or EAM visualization by a single operator. The procedures included atrial fibrillation ( n = 33), atrial tachycardia ( n = 8), and ventricular tachycardia ( n = 1) ablations. Fourteen of 41 patients had congenital heart disease, including 9 patients with previous septal closure. Twenty-two patients had at least one previous TSP. All TSPs were performed successfully and without complications. The overall median fluoroscopy time amounted to 3.2 min and median exposure of 199.5 µ Gy∗m 2 . In a subgroup of patients ( n = 27), the RF needle was visualized on the EAM system: median radiation time was 0.88 (interquartile range: 0–3.4) min and median exposure 33.5 [0–324.8] µ Gy∗m 2 . Conclusions . TSP using an RF needle is an effective technique, also in congenital patients with artificial patch material and in normal patients with multiple previous TSPs. Moreover, the RF needle tip visualization on EAM allows a low (or even zero) fluoroscopy approach.
No takes yet. Share an insight, caveat, or question.
Guarguagli et al. (2020) conducted an observational in Left-sided cardiac arrhythmias requiring catheter ablation (atrial fibrillation, atrial tachycardia, ventricular tachycardia) (n=41). Radiofrequency (RF) needle transseptal puncture guided by fluoroscopy and/or 3D electroanatomical mapping (EAM) visualization was evaluated on Transseptal puncture acute procedural success rate without complications. Radiofrequency needle transseptal puncture achieved 100% success without complications and 0.88 min median fluoroscopy time with 3D mapping visualization.
Synapse has enriched 10 related papers. Consider them for comparative context: