Key result
Transseptal puncture using a radiofrequency needle was 100% successful with no complications in 42 procedures, and EAM visualization enabled very low radiation exposure.
Why the study?
To evaluate the safety, usefulness, and radiation exposure of direct radiofrequency needle tip visualization on a 3D electroanatomical mapping system during transseptal puncture in an unselected patient cohort.
Does transseptal puncture using a radiofrequency needle with electroanatomical mapping visualization improve safety and reduce radiation exposure in patients undergoing left-sided ablation?
Observational (n=41)
Does transseptal puncture using a radiofrequency needle with electroanatomical mapping visualization improve safety and reduce radiation exposure in patients undergoing left-sided ablation?
Transseptal puncture using a radiofrequency needle with 3D electroanatomical mapping visualization is safe, effective, and facilitates a low-fluoroscopy approach, even in patients with prior septal closures or multiple previous punctures.
Supports feasibility of RF transseptal puncture with minimal radiation; leaves open randomized comparison to conventional techniques.
Introduction . Transseptal puncture (TSP) is a routine access route in patients with left-sided ablation substrates and is performed safely on fluoroscopy (+/− echocardiographic guidance). We report on our experience using a radiofrequency (RF) needle in an unselected group of patients to demonstrate safety and usefulness of direct tip visualization on the 3D electroanatomical mapping (EAM) system with specific emphasis on total radiation exposure. Methods and Results . We retrospectively reviewed 42 consecutive left-sided ablation procedures with TSP performed using an RF needle guided by fluoroscopy and/or EAM visualization by a single operator. The procedures included atrial fibrillation ( n = 33), atrial tachycardia ( n = 8), and ventricular tachycardia ( n = 1) ablations. Fourteen of 41 patients had congenital heart disease, including 9 patients with previous septal closure. Twenty-two patients had at least one previous TSP. All TSPs were performed successfully and without complications. The overall median fluoroscopy time amounted to 3.2 min and median exposure of 199.5 µ Gy∗m 2 . In a subgroup of patients ( n = 27), the RF needle was visualized on the EAM system: median radiation time was 0.88 (interquartile range: 0–3.4) min and median exposure 33.5 [0–324.8] µ Gy∗m 2 . Conclusions . TSP using an RF needle is an effective technique, also in congenital patients with artificial patch material and in normal patients with multiple previous TSPs. Moreover, the RF needle tip visualization on EAM allows a low (or even zero) fluoroscopy approach.
No takes yet. Share an insight, caveat, or question.
Guarguagli et al. (2020) conducted an observational in Left-sided ablation substrates requiring transseptal puncture (n=41). Radiofrequency needle for transseptal puncture was evaluated on Procedural success and complications. Transseptal puncture using a radiofrequency needle was 100% successful with no complications in 42 procedures, and EAM visualization enabled very low radiation exposure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: