Key result
Nested PCR outperforms other amplification methods for enterovirus detection, achieving adequate proficiency in ~66% of datasets.
Why the study?
Nucleic acid amplification methods are widely used for enterovirus detection, but reliable molecular diagnosis requires assay standardization and continuous monitoring of sensitivity and specificity across laboratories.
Do nucleic acid amplification methods used across European diagnostic laboratories reliably detect enteroviruses in a standardized proficiency panel?
Do nucleic acid amplification methods used across European diagnostic laboratories reliably detect enteroviruses in a standardized proficiency panel?
Substantial variation in enterovirus PCR performance across diagnostic laboratories (with 34% performing inadequately) underscores the necessity for ongoing external quality control and standardization.
Answers are grounded in this paper and cite their sources.
Enterovirus PCR results warrant cautious clinical interpretation due to variable lab proficiency; leaves open optimal standardization approaches.
A multicenter study of molecular detection of enteroviruses was conducted using a proficiency panel. Of 70 data sets, 46 (66%) reported correct results for samples containing at least 1 50% infective dose per mi and for negative samples. Variation in performance between laboratories demonstrates the need for ongoing quality control. Original language English Pages (from-to) 3390-3392 Number of pages 3 Journal Journal of clinical microbiology Volume 39 Issue number 9 DOIs https://doi.org/10.1128/JCM.39.9.3390-3392.2001 Publication status Published - 21 Sept 2001 Keywords Enterovirus Enterovirus Infections Humans Laboratories Nucleic Acid Amplification Techniques Quality Control RNA, Viral
No takes yet. Share an insight, caveat, or question.
Vliet et al. (2001) studied Enterovirus infection (molecular diagnostic proficiency testing) (n=70). Nucleic acid amplification methods (including nested PCR, Roche Amplicor EV-PCR, and in-house PCR) for enterovirus detection vs. Different PCR methodologies (nested PCR vs other PCR methods) and reference viral infectivity titers was evaluated on Adequate laboratory proficiency (correct results for all strongly positive samples containing >= 1 TCID50/ml of original virus stock and all negative samples) (p=0.011). Nucleic acid amplification methods achieved adequate enterovirus detection proficiency in 46 of 70 data sets, with nested PCR outperforming other PCR methods.
Synapse has enriched 10 related papers. Consider them for comparative context: