Why the study?
Fontan patients may have abnormal diastolic function, but it is poorly characterized using conventional echocardiography.
Are atrial and ventricular diastolic strain parameters altered in pediatric Fontan patients compared to healthy controls, and do they differ by ventricular morphology?
Are atrial and ventricular diastolic strain parameters altered in pediatric Fontan patients compared to healthy controls, and do they differ by ventricular morphology?
Pediatric Fontan patients exhibit significantly altered atrial and diastolic strain parameters compared to healthy controls, with more pronounced derangements in those with right ventricular morphology.
Answers are grounded in this paper and cite their sources.
Diastolic strain differences in Fontan patients are hypothesis-generating; leaves open their prognostic value before clinical adoption.
BACKGROUND: Fontan patients may have abnormal diastolic function, but this is poorly characterized using conventional echocardiography. Herein, we describe atrial function and other diastolic strain measurements in a cohort of pediatric Fontan patients, with comparisons to healthy controls and between right ventricle (RV) and left ventricle (LV) types. METHODS: This is a single-institution, cross-sectional study of healthy controls (n = 50) and patients with a Fontan circulation (n = 50, 29 RV type, 21 LV type). Parameters of atrial function and ventricular systolic and diastolic function derived from speckle-tracking echocardiography (STE) were retrospectively obtained from apical four-chamber images. These included three phases of atrial strain (Ɛ) and strain rate (SR): contraction (ac), conduit (con), and reservoir (res), and diastolic SR for passive (E-SR) and active (A-SR) filling. RESULTS: Fontan patients had lower Ɛcon (13.4% vs. 28.2%, p < 0.01) and Ɛres (22.8% vs. 37.7%, p < 0.01) compared to controls. They had a longer time to peak atrial filling (450 ms vs. 399 ms, p < 0.01) and a greater reliance on atrial contraction for ventricular filling (atrial contraction fraction 41% vs. 26%, p < 0.01). RV type Fontan patients had longer time to peak atrial filling (461 ms vs. 406 ms, p = 0.02) and lower E-SR (1.0 %/s vs. 1.4%/s, p = 0.01) compared to LV type. CONCLUSIONS: Several atrial and diastolic strain parameters in pediatric Fontan patients are altered compared to controls. Additionally, some metrics are more deranged in RV type Fontan patients. This highlights the need for population-specific normal values in patients with a Fontan circulation. Study of the clinical correlations and prognostic value of these STE-derived parameters is also warranted.
No takes yet. Share an insight, caveat, or question.
Loar et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: