Key result
Simulation results showed that pacing efficacy depended on the chosen metric; for example, biventricular pacing improved QRS duration from 120 to 90 ms but produced activation maps that deviated most from physiological patterns.
Why the study?
Current ventricular resynchronisation assessment relies largely on ECG-based metrics that do not fully capture electrical synchrony complexity or physiological activation sequence restoration.
Does conduction system pacing improve ventricular resynchronisation compared to biventricular pacing in a computational model of bundle branch block?
Does conduction system pacing improve ventricular resynchronisation compared to biventricular pacing in a computational model of bundle branch block?
The apparent efficacy of ventricular pacing strategies is highly dependent on the evaluation metric used, demonstrating that single-domain measures like QRS duration cannot fully capture the complexity of resynchronisation.
Answers are grounded in this paper and cite their sources.
Metric choice determines apparent pacing efficacy; leaves open optimal resynchronisation strategy pending multi-domain validation.
Background Current evaluation of ventricular resynchronisation relies largely on ECGbased metrics, which do not fully capture the complexity of electrical synchrony. Reliance on a single clinical metric provides limited insight into the restoration of the intrinsic physiological activation sequence. To address this, we employed high-fidelity computational simulations using a multiple-metrics framework to mechanistically compare established pacing strategies. Methods A high-resolution, anatomically and biophysically detailed four-chamber human model was used to compare the resynchronisation efficacy of conduction system pacing and biventricular pacing under focal bundle branch block. Outcomes were evaluated using: (1) ECG markers (QRS duration, Hisio-ventricular interval, V6-V1 interpeak interval, V6 R-wave peak time); (2) high-density activation maps; and (3) ventricular activation velocity, a novel metric of depolarisation dynamics. Results Simulation results showed that pacing efficacy depended on the chosen metric. biventricular pacing improved ECG markers (e.g., QRS 120 to 90 ms) and activation velocity, but activation maps deviated most from physiological patterns. conduction system pacing produced maps resembling normal sinus rhythm, though velocity profiles showed residual dyssynchrony, highlighting that improvement on one metric did not guarantee improvement on another. Conclusion These findings show that pacing efficacy depends on the evaluation metric and that single-metric assessment cannot capture the complex dynamics of ventricular resynchronisation. Patient-specific computational modelling offers a promising approach for non-invasive, multi-modal in silico evaluation.
No takes yet. Share an insight, caveat, or question.
Kariman et al. (2026) studied Bundle branch block (n=1). Pacing strategies (conduction system pacing and biventricular pacing) vs. Unpaced bundle branch block and normal sinus rhythm was evaluated on Resynchronisation efficacy evaluated by ECG markers, activation maps, and activation velocity. Simulation results showed that pacing efficacy depended on the chosen metric; for example, biventricular pacing improved QRS duration from 120 to 90 ms but produced activation maps that deviated most from physiological patterns.
Synapse has enriched 10 related papers. Consider them for comparative context: