Why the study?
Data addressing the presence of inter-vendor discrepancies for left ventricular mechanical dispersion (LVMD) were lacking.
Does vendor independent software reduce inter-vendor variability in left ventricular mechanical dispersion assessment compared to vendor specific software?
Does vendor independent software reduce inter-vendor variability in left ventricular mechanical dispersion assessment compared to vendor specific software?
Serial measurements of left ventricular mechanical dispersion should be performed using a single vendor or vendor-independent software due to significant inter-vendor variability with vendor-specific software.
Answers are grounded in this paper and cite their sources.
Inter-vendor LVMD differences may limit clinical use for arrhythmic risk prediction; leaves open need for standardized protocols across platforms.
PURPOSE: Left ventricular mechanical dispersion (LVMD) is a novel speckle tracking parameter for prognostic assessment of arrhythmic risk prediction. There is growing evidence to support its use in a variety of cardiomyopathic processes. There is paucity of data addressing any presence of inter-vendor discrepancies for LVMD. The aim of this study was to assess inter-vendor variability of LVMD in vendor specific software (VSS) and vendor independent software (VIS) in subjects with preserved and reduced left ventricular function. METHODS: Fifty-nine subjects (14 normal subjects and 45 subjects with cardiac disease) were recruited and 2D speckle tracking echocardiographic images were acquired on two different ultrasound machines (GE and Philips). LVMD was measured by two different VSS (EchoPac GE and QLAB Philips) and one VIS (TomTec Arena). RESULTS: There was significant bias and wide limits of agreement (LOA) in the overall cohort observed between two different VSS (17.6 ms; LOA: -29.6 to 64.8; r: .47). There was acceptable bias and narrower LOA with good agreement for LVMD between images obtained on different vendors when performed on VIS (-3.1 ms; LOA: -27.6 to 21.4; r: .75). QLAB LVMD was consistently higher than GE LVMD and TomTec LVMD in both preserved and reduced left ventricular function. LVMD measurements have high intra-vendor reproducibility with excellent inter and intra-observer agreement. CONCLUSIONS: There was acceptable bias and narrower LOA for LVMD assessment on a VIS. Inter-vendor variability exists for LVMD assessment between VSS. Serial measurements of LVMD should be performed using a single vendor for consistent and reliable results.
No takes yet. Share an insight, caveat, or question.
Appadurai et al. (2021) studied this question.