Why the study?
Does a 30-electrode array better discriminate changes in heterogeneity of repolarization compared to a 12-lead standard ECG in a rabbit heart model?
Does a 30-electrode array better discriminate changes in heterogeneity of repolarization compared to a 12-lead standard ECG in a rabbit heart model?
A 30-electrode array better discriminates changes in repolarization heterogeneity compared to a standard 12-lead ECG in an in vitro rabbit heart model.
Answers are grounded in this paper and cite their sources.
Multi-electrode arrays may enhance repolarization heterogeneity detection in animal models; leaves open translation to clinical ECG risk stratification.
Background: QT interval dispersion (QTID) as assessed on conventional surface electrocardiogram (ECG) has been used as a clinical tool to identify patients at high risk of ventricular arrhythmia. However, the results obtained have been controversial. The main purpose of this study was to compare QTID measured from an array of 5 × 6 electrodes homogeneously distributed against the values found when the 12‐lead standard ECG was used. Methods: QTID was calculated in a modified Langendorff‐perfused rabbit heart model immersed in a cylindrical chamber. Dispersion in ventricular repolarization was artificially increased by d‐sotalol (60 μ;m) perfusion. Results: All the duration variables measured from any of the lead systems used were significantly increased after d‐sotalol perfusion. The most commonly used variables in clinical studies, such as QTID (maximum ‐ minimum), do not reach a level of statistical significance, except when measured from the 30‐electrodes array or 15 electrodes covering the left or right side of the heart. The standard deviation of the QT interval (QTI) hardly reached a significant level (P = 0.0499) when calculated from the 12‐lead standard ECG. QTID measured at the peak of the T wave exhibited the highest level of significance when calculated from any of the lead systems used. Conclusion: Thirty electrodes homogeneously distributed on the body surface can better discriminate changes in heterogeneity of repolarization. These data further support the importance of multiple recording systems for the evaluation of QTID and may help to provide an understanding of the discrepancies found in clinical applications.
No takes yet. Share an insight, caveat, or question.