Key result
An automated algorithm for tissue Doppler echocardiography analysis demonstrated strong agreement with expert human operators (mean difference 0.48 ± 1.12 cm/s) while being 10-fold faster (p < 0.001).
Why the study?
Does an automated algorithm provide tissue Doppler velocity measurements as accurately and more quickly than expert human operators in patients undergoing echocardiography?
Observational (n=48)
No
Does an automated algorithm provide tissue Doppler velocity measurements as accurately and more quickly than expert human operators in patients undergoing echocardiography?
Mean Difference: 0.48
An open-source, automated algorithm can accurately and rapidly measure multi-beat tissue Doppler velocities, matching human expert precision while significantly reducing analysis time.
Current guidelines for measuring cardiac function by tissue Doppler recommend using multiple beats, but this has a time cost for human operators. We present an open-source, vendor-independent, drag-and-drop software capable of automating the measurement process. A database of ~8000 tissue Doppler beats (48 patients) from the septal and lateral annuli were analyzed by three expert echocardiographers. We developed an intensity- and gradient-based automated algorithm to measure tissue Doppler velocities. We tested its performance against manual measurements from the expert human operators. Our algorithm showed strong agreement with expert human operators. Performance was indistinguishable from a human operator: for algorithm, mean difference and SDD from the mean of human operators’ estimates 0.48 ± 1.12 cm/s (R 2 = 0.82); for the humans individually this was 0.43 ± 1.11 cm/s (R 2 = 0.84), −0.88 ± 1.12 cm/s (R 2 = 0.84) and 0.41 ± 1.30 cm/s (R 2 = 0.78). Agreement between operators and the automated algorithm was preserved when measuring at either the edge or middle of the trace. The algorithm was 10-fold quicker than manual measurements (p < 0.001). This open-source, vendor-independent, drag-and-drop software can make peak velocity measurements from pulsed wave tissue Doppler traces as accurately as human experts. This automation permits rapid, bias-resistant multi-beat analysis from spectral tissue Doppler images.
No takes yet. Share an insight, caveat, or question.
Dhutia et al. (2017) conducted an observational in Patients undergoing echocardiography (n=48). Automated multi-beat tissue Doppler echocardiography analysis algorithm vs. Manual measurements by expert echocardiographers was evaluated on Agreement of peak velocity measurements with human consensus (mean difference) (MD 0.48 cm/s). An automated algorithm for tissue Doppler echocardiography analysis demonstrated strong agreement with expert human operators (mean difference 0.48 ± 1.12 cm/s) while being 10-fold faster (p < 0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: